Pipe runs
Don’t forget to use a mitre box to cut your PVC pipes at at perfect 90° angle.
We also advise you to use the deburring tool on your PVC pipes to make sure
that the inside is exceptionally smooth.
Do not join pipe run until you have enough pipe length to hold the hose. For
example, if using a 12 m hose, install at least 13.5 m of pipe before connec-
ting to another pipe run.
In order to ensure enough pipe to store the hose, the pipe runs will someti-
mes need to make a loop before heading back to the power unit.
When installing the pipe straps to secure the piping
in place, make sure not to squeeze the pipes (fi gure
7), so as not to alter the movement of the hose inside
the piping system.