TECNORD
RC-DBX/PCM/NBM
Use and Maintenance Manual
Page
18/23
The following table shows all the displayed codes:
Displayed code for Microswitch open Displayed code for Microswitch closed Displayed Digital Input
0_O 0_C
IN0
1_O 1_C
IN1
When no operation is activated the Receiver automatically switches to the Normal Display Menu after 60s, otherwise a new power-
on is required in order to get out of this menu.
8.2.4
Current Display Menu
This paragraph is applicable only to systems that implement a proportional trigger.
This menu is accessed from the Normal Display Menu with the following procedure: push the proportional trigger to its maximum
level, then activate the 1A (first actuator from the left towards up) and 4B (fourth actuator from the left towards down) movements
simultaneously for at least 5 seconds.
In this menu, when no operation is active the indication “Cur” is displayed. When a movement is active the value of the current (in
mA) that is set for the proportional valve is displayed.
Example: indication without any active movement
Example: indication with an active movement and with 523mA set
for the proportional valve
When no operation is activated the Receiver automatically switches to the Normal Display Menu after 60s, otherwise a new power-
on is required in order to get out of this menu.
8.2.5
Remote Control Unit Display Menu
This menu is accessed from the Normal Display Menu with the following procedure: push the proportional trigger to its maximum
level, then activate the 1A (first actuator from the left towards up) and 2B (second actuator from the left towards down) movements
simultaneously for at least 5 seconds.
In this menu, when no operation is active the indication “_ _ _” is displayed. When a movement is active the state of the contact
that activated the movement in the SHW-TX Transmitter is displayed. For each of the contacts the following state is displayed:
C closed
In case of a multiple command (two or more movements activated simultaneously) only the state of one of the active commands is
displayed, following an internal priority scheme.
Example: indication without any active function
Example: indication when the contact 1A is closed on the SHW-TX
The following table shows all the displayed codes:
Display Displayed
Status
C1A
closed contact 1A
C1b
closed contact 1B
C2A
closed contact 2A
C2b
closed contact 2B
C3A
closed contact 3A
C3b
closed contact 3B
C4A
closed contact 4A
C4b
closed contact 4B
C5A
closed contact 5A
C5b
closed contact 5B
CEA
closed Engine Start
CEb
closed Rngine Stop
When no operation is activated the Receiver automatically switches to the Normal Display Menu after 60s, otherwise a new power-
on is required in order to get out of this menu.