In the locked position, there should be approximately 1 mm
clearance between the lock bolt and the cavity in
the blocking bar of the boltwork. The bolt must be
able to move freely without force being applied to
it.
In open position, there should be
minimum 3mm and maximum 5 mm
clearance between the lock bolt and
the blocking bar of the boltwork.
The spring-latch version ( Motor SpringBolt) is specially designed to ensure self locking when
the door closes.
The distance between the SpringBolt lock and the locking edge must be
between a minimum of 3 mm and a maximum of 8 mm.
In open position, there should be
minimum 3mm and maximum 5 mm
clearance between the lock bolt and
the blocking bar of the boltwork.
Connect the keypad cable to the lock connector "1", making sure it
is fully inserted and locked.
Any alarm interface or battery holder will be connected to the lock
connector “2”.
To remove the cable, bring the connector upwards and carefully pull
it out.