background image

 

 
 
 

6 of 20 

 

II_ DigiTech_01_eng 

Installation instructions 

 

         

DigiTech

 

Important notes

!

  

 

 

Before  installing  this  product,  please  read  carefully  the  installation  and  operating 

instructions. 

 

Locks can be installed in all traditional safes. 

 

Lock has to be mounted on secure storage metal (preferred steel) units only.  

 

Locks must be protected against external attacks, for this reason it is recommended to 

install them on the door away from any through holes. 

 

Any electronic part must be properly protected and not easily accessible even when 

the door is open. 

 

Locks have been developed to work correctly in a temperature range from -5 ° C to + 50 

° C and in an environment with non-condensing humidity between 25% and 90%. 

 

The mounting dimensions are standard (magic module). 

 

For  the  installation  of  the  keypad  and  lock,  use  only  the  screws  provided  by 

Tecnosicurezza. Any other screw must be approved in advance. 

 

Locks are supplied with metric (M6) mounting screws. Upon request, Imperial 1/4-20 UNC 

format mounting screws are available. 

 

The type of material and the length of the screws must, in any case, be selected so as to 

guarantee long life and reliability. 

 

Tighten  the  screws  so  that  the  lock  is  firmly  fixed  to  the  mounting  surface 

(recommended torque between 2.5 and 5.5 Nm). 

 

The mounting surface must be perfectly flat. 

 

In  order  to  prevent  loosening  of  the  screws  it  is  recommended  the  use  of  LOCTITE® 

threadlocker and/or specific washers positioned under the head of the fixing screw. 

 

The  diameter  of  the  passage  hole  for  the  connection  cable  or  the  spindle  must  not 

exceed 11 mm. 

 

The hole must be completely cleaned of drill dust and no edge should be sharp. 

 

 

Summary of Contents for DigiTech Series

Page 1: ...DigiTech Installation instructions ...

Page 2: ...igh technology and reliability systems which continue to receive the approval of an increasingly demanding clientele TECNOSICUREZZA is present directly on the Italian Spanish and US markets and through a extensive distribution network in many European and extra European countries TECNOSICUREZZA is aimed at national and international customers of primary importance such as banks safe manufacturers ...

Page 3: ...D DIMENSIONS 7 ROTOBOLT LOCK DIMENSIONS 8 STRAIGHTBOLT LOCK DIMENSIONS 8 SPRINGBOLT LOCK DIMENSIONS 9 MOTORLOCK DIMENSIONS 9 MOTORSPRINGBOLT LOCK DIMENSIONS 9 FIXED KEYPAD INSTALLATION INSTRUCTIONS 10 ROTOBOLT LOCK INSTALLATION INSTRUCTIONS 10 STRAIGHTBOLT AND SPRINGBOLT LOCKS INSTALLATION INSTRUCTIONS 11 MOTORLOCK AND MOTOR SPRINGBOLT LOCKS INSTALLATION INSTRUCTIONS 12 FUNCTIONAL TEST 14 CE DECLA...

Page 4: ...L4001 Large battery box for 6 size C 1 5V batteries T6005 W Power supply interface 12Vdc T6005 Power supply interface 12Vdc with alarm interface L2666 Knob with 6 mm square spindle N1982 User Dallas key Audit and programming accessories Code Description N42180 T Interfaccia USB N42170 D Dallas key reader with molex connector N42170 J Dallas key reader with jack connector N42170 M Magnetic Dallas k...

Page 5: ...II_DigiTech_01_eng 5 of 20 Installation instructions DigiTech Certificazions ...

Page 6: ...sions are standard magic module For the installation of the keypad and lock use only the screws provided by Tecnosicurezza Any other screw must be approved in advance Locks are supplied with metric M6 mounting screws Upon request Imperial 1 4 20 UNC format mounting screws are available The type of material and the length of the screws must in any case be selected so as to guarantee long life and r...

Page 7: ... using cable ties and cable ties bases If placed in normal domestic or office environments the locks do not require particular maintenance in any case after 10 000 opening closing cycles it is recommended to run a test that verifies the correct and complete operation of the product Use only DURACELL 9 Volt Alkaline batteries or battery holders with DURACELL 1 5 Volt Alkaline batteries Alternativel...

Page 8: ...8 of 20 II_ DigiTech_01_eng Installation instructions DigiTech STANDARD mounting VERTICAL mounting RotoBolt lock dimensions StraightBolt lock dimensions ...

Page 9: ...II_DigiTech_01_eng 9 of 20 Installation instructions DigiTech SpringBolt lock dimensions MotorLock dimensions MotorSpringBolt lock dimensions ...

Page 10: ...the keypad battery compartment or if provided connect the battery pack to the lock connector BAT connector 2 in the case of a MotorLock or Motor SpringBolt lock RotoBolt lock installation instructions The RotoBolt lock is a swingbolt lock whose block is carried out by a motor it can be installed in all 4 directions even upside down By entering a valid code the lock electronic removes the blocking ...

Page 11: ...knob a handle or directly to the keypad if equipped with a rotation kit When the spindle is brought to the locked position the bolt comes out ensuring the lock is locked The StraightBolt and SpringBolt locks can be mounted in all four mounting directions In the locked position there should be approximately 1 mm clearance between the lock bolt and the cavity in the blocking bar of the boltwork The ...

Page 12: ...iven dead bolt and a motor driven spring bolt whose block is carried out by a motor By entering a valid code the motor retracts the bolt which remains in the open position for about 8 seconds and then automatically returns to the locked position If the manual relocking option is selected the bolt closes by pressing and holding the button The distance between the SpringBolt lock and the locking edg...

Page 13: ...k The spring latch version Motor SpringBolt is specially designed to ensure self locking when the door closes The distance between the SpringBolt lock and the locking edge must be between a minimum of 3 mm and a maximum of 8 mm In open position there should be minimum 3mm and maximum 5 mm clearance between the lock bolt and the blocking bar of the boltwork Connect the keypad cable to the lock conn...

Page 14: ...pen position For all types of locks the bolt must be able to move freely LOCKING With RotoBolt and MotorLock locks turn the safe door handle to the locked position Lock bolt must fully extend and ensure locking With MotorLock locks with manual relocking turn the door handle towards the locked position and press the button Lock bolt must fully extend and ensure locking With StraightBolt lock rotate...

Page 15: ... seguenti norme armonizzate EN 61000 6 3 EN50130 4 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 11 EN 61000 6 1 EN55022 The undersigned Mr Franco Miller as Chairman and Legal Representative of the company Tecnosicurezza s r l located in San Giovanni Lupatoto Verona Via Cesare Battisti 276 declare herewith on our own responsibility that the above mentioned product mee...

Page 16: ...i norme armonizzate EN 61000 6 3 EN50130 4 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 11 EN 61000 6 1 EN55022 The undersigned Mr Franco Miller as Chairman and Legal Representative of the company Tecnosicurezza s r l located in San Giovanni Lupatoto Verona Via Cesare Battisti 276 declare herewith on our own responsibility that the above mentioned product meets the r...

Page 17: ...II_DigiTech_01_eng 17 of 20 Installation instructions DigiTech NOTES ...

Page 18: ...18 of 20 II_ DigiTech_01_eng Installation instructions DigiTech NOTES ...

Page 19: ...II_DigiTech_01_eng 19 of 20 Installation instructions DigiTech NOTES ...

Page 20: ...olled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Contacts GLOBAL HEADQUARTERS USA HEADQUARTERS SPAIN HEADQUARTERS Tecnosicurezza SpA Tecnosicurezza Inc Tecnosicurezza Sa Via Cesare Battisti 276 50 Thomas Lane C Menor 4 Nave 10 37057 San Giovanni Lupatoto Verona Versailles KY 40383 Pol Ind La Mina ...