background image

 

 

 

 

 
 
 

 

Correct disposal of this product: 

(Waste Electrical & Electronic Equipment) 

 

Applicable in the European Union and other European countries with separate collection systems. 

 

 
 
 

 
 

This marking displayed on the product or its literature indicates that it should not be disposed with other wastes at the end of its 

working life. 

To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other 

types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. 

 

 
 
 
 
 
 
 
 
 
 
 
 

Contacts 

 

GLOBAL HEADQUARTERS 

USA HEADQUARTERS 

SPAIN HEADQUARTERS 

Tecnosicurezza SpA

 

Tecnosicurezza Inc.

 

Tecnosicurezza Sa

 

Via Cesare Battisti, 276

 

50, Thomas Lane

 

C/Menor, 4 - Nave 10

 

37057 San Giovanni Lupatoto 

Verona

 

Versailles, KY 40383

 

Pol. Ind La Mina 28770 

Colmenar Viejo

 

Tel.+39 045 826 64 70 

Tel.+1 859 490 89 30

 

Tel.+34 91 804 33 91

 

Fax. +39 045 826 64 69

 

 

Fax.+34 91 804 32 63

 

info@tecnosicurezza.it

 

info@usatecno.com

 

info@tecnosicurezza.es

 

 
 

Summary of Contents for Pulse

Page 1: ...Pulse User Instructions ...

Page 2: ...gh technology and reliability systems which continue to receive the approval of an increasingly demanding clientele TECNOSICUREZZA is present directly on the Italian Spanish and US markets and through a extensive distribution network in many EU and extra EU countries TECNOSICUREZZA is aimed at national and international customers of primary importance such as banks safe manufacturers cash in trans...

Page 3: ...HANGE CODE 7 INSTALL DISABLE DELETE USERS 8 INSTALL USERS FUNCTION 1 8 DISABLE ENABLE USERS FUNCTION 2 8 DELETE USERS FUNCTION 3 8 TEST MODE 8 USERS STATUS 9 AUDIT CONFIGURATION DOWNLOAD 9 TIME DELAY AND OPEN WINDOW 9 LOCK RESET 10 CORRECT DISPOSAL OF THIS PRODUCT 12 CONTACTS 12 Before operating the lock please read this manual thoroughly and retain it for future reference ...

Page 4: ...mmended to run a test that verifies the correct and complete operation of the product Use only DURACELL 9 Volt Alkaline batteries or battery holders with DURACELL 1 5 Volt Alkaline batteries Alternatively it is possible to use a 12VDC 1A power adapter p n N1212 with relative power supply interface p n T6005 W or p n T6005 A series of multiple beeps indicate a low battery level which need immediate...

Page 5: ...also by inputing 555555 code in this case the silent alarm is activated by increasing the last digit by one number of the code 555556 In pre setup mode programming can be performed through a Dallas key or by selecting one of the following 4 preloaded configurations No configuration Maximum number of users Dual code 0 2 No 1 9 No 2 2 Si 3 9 Si Note this programming procedure is not valid for EM6050...

Page 6: ...ng this period the LED flashes once every 10s Each time a key is pressed a long beep is produced and no operation is allowed Dallas keys During the installation function 1 a Dallas key model 1982 can be associated to a user by simply placing it in the Dallas reader after entering the ID and related code The user is then identified by numeric code Dallas key Power supply Lock can be powered with an...

Page 7: ...f time delay the open window counting begins Enter a code during the opening window 2 codes in case of dual code opening The keypad beeps twice and the lock can be opened Override user Enter a opening code Time delay counting begins Input the override user code and the Dallas key if programmed or the override Dallas key if only Dallas override user The keypad beeps twice and the lock can be opened...

Page 8: ...ring the open window counting Disable Enable users function 2 Hold press util the double beep Led remains on Enter the Manager code and the Dallas key if programmed The keypad beeps twice All the users but Manager are disabled enabled Delete users function 3 Hold press util the double beep Led remains on Enter the Manager code and the Dallas key if programmed The keypad beeps twice Enter the numbe...

Page 9: ...ches OFF Audit configuration download Audit and configuration can be downloaded on a Dallas key previously programmed with DiaLog software and they can be downloaded on a PC through the USB interface provided by Tecnosicurezza Hold press util the double beep Led remains on Enter the Manager code and the Dallas key if programmed The keypad beeps twice Insert the audit Dallas key into the reader and...

Page 10: ...utes the open window in between 1 and 19 minutes Note it s possible to reduce the time delay only during the open window counting Lock reset The reset operation will restore the system in pre setup mode Disconnect the power supply Press keys to discharge the excess current Connect the reset box on the secondary connector of the lock BAT or 2 Power up the reset box with a 9V battery The keypad beep...

Page 11: ...IU_Pulse_01_eng 11 of 12 User instructions Pulse NOTES ...

Page 12: ...olled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Contacts GLOBAL HEADQUARTERS USA HEADQUARTERS SPAIN HEADQUARTERS Tecnosicurezza SpA Tecnosicurezza Inc Tecnosicurezza Sa Via Cesare Battisti 276 50 Thomas Lane C Menor 4 Nave 10 37057 San Giovanni Lupatoto Verona Versailles KY 40383 Pol Ind La Mina ...