General information 

 

Using the keypad 

 

To  start  a  time  delay  counting  (if  programmed),  enter  an  opening 
combination: LED flashes every 2s, indicating the counting. 

 

 

 

 

 

 

Press any key to stop the time delay counting. 

 

 

 

 

 

 

 

 

The opening window is indicated by a flashing and a beep alternating at 
1s intervals. 

 

 

 

 

 

 

 

 

The led remains on if the system is in programming mode.

 

 

 

 

 

 

 

2 short beeps are produced if an operation/code is correct. 

 

 

 

 

 

 

 

 

A long beep is produced if an operation/code is incorrect.

 

 

 

 

 

 

If an incorrect operation is performed, wait 5 seconds until the led switches off and try again.

 

 
Pre-setup & Configurations 

 

In pre-setup mode, press 1 to open the lock and activate the silent alarm. It’s possible to open 
also by inputing 555555 code, in this case the silent alarm is activated by increasing the last 
digit by one number of the code (555556).  
In pre-setup mode, programming can be performed through a Dallas key or by selecting one of 
the following 4 preloaded configurations: 

 

 

No. configuration 

Maximum number of users 

Dual code 

 

 

No 

 

 

No 

 

 

Si 

 

 

Si 

 

 

Note

: this programming procedure is not valid for EM6050 locks. 

 

Silent alarm option can be activated in pre-setup mode thanks to a setup Dallas key, or by simply 
connecting an alarm interface to the lock and entering an opening code. 

 

Select a keypad configuration (only in pre-setup status) 

 

 

Hold press the 2 key for few seconds, enter the code 555555 and select the desired 
configuration number. 

 

At the end of the configuration only the Manager is installed, with code 123456. 

 

If all users are blocked and only the manager is enabled, time delay and dual code (if 
programmed) are not available.

 

 

 

 

Summary of Contents for Pulse

Page 1: ...Pulse User Instructions ...

Page 2: ...gh technology and reliability systems which continue to receive the approval of an increasingly demanding clientele TECNOSICUREZZA is present directly on the Italian Spanish and US markets and through a extensive distribution network in many EU and extra EU countries TECNOSICUREZZA is aimed at national and international customers of primary importance such as banks safe manufacturers cash in trans...

Page 3: ...HANGE CODE 7 INSTALL DISABLE DELETE USERS 8 INSTALL USERS FUNCTION 1 8 DISABLE ENABLE USERS FUNCTION 2 8 DELETE USERS FUNCTION 3 8 TEST MODE 8 USERS STATUS 9 AUDIT CONFIGURATION DOWNLOAD 9 TIME DELAY AND OPEN WINDOW 9 LOCK RESET 10 CORRECT DISPOSAL OF THIS PRODUCT 12 CONTACTS 12 Before operating the lock please read this manual thoroughly and retain it for future reference ...

Page 4: ...mmended to run a test that verifies the correct and complete operation of the product Use only DURACELL 9 Volt Alkaline batteries or battery holders with DURACELL 1 5 Volt Alkaline batteries Alternatively it is possible to use a 12VDC 1A power adapter p n N1212 with relative power supply interface p n T6005 W or p n T6005 A series of multiple beeps indicate a low battery level which need immediate...

Page 5: ...also by inputing 555555 code in this case the silent alarm is activated by increasing the last digit by one number of the code 555556 In pre setup mode programming can be performed through a Dallas key or by selecting one of the following 4 preloaded configurations No configuration Maximum number of users Dual code 0 2 No 1 9 No 2 2 Si 3 9 Si Note this programming procedure is not valid for EM6050...

Page 6: ...ng this period the LED flashes once every 10s Each time a key is pressed a long beep is produced and no operation is allowed Dallas keys During the installation function 1 a Dallas key model 1982 can be associated to a user by simply placing it in the Dallas reader after entering the ID and related code The user is then identified by numeric code Dallas key Power supply Lock can be powered with an...

Page 7: ...f time delay the open window counting begins Enter a code during the opening window 2 codes in case of dual code opening The keypad beeps twice and the lock can be opened Override user Enter a opening code Time delay counting begins Input the override user code and the Dallas key if programmed or the override Dallas key if only Dallas override user The keypad beeps twice and the lock can be opened...

Page 8: ...ring the open window counting Disable Enable users function 2 Hold press util the double beep Led remains on Enter the Manager code and the Dallas key if programmed The keypad beeps twice All the users but Manager are disabled enabled Delete users function 3 Hold press util the double beep Led remains on Enter the Manager code and the Dallas key if programmed The keypad beeps twice Enter the numbe...

Page 9: ...ches OFF Audit configuration download Audit and configuration can be downloaded on a Dallas key previously programmed with DiaLog software and they can be downloaded on a PC through the USB interface provided by Tecnosicurezza Hold press util the double beep Led remains on Enter the Manager code and the Dallas key if programmed The keypad beeps twice Insert the audit Dallas key into the reader and...

Page 10: ...utes the open window in between 1 and 19 minutes Note it s possible to reduce the time delay only during the open window counting Lock reset The reset operation will restore the system in pre setup mode Disconnect the power supply Press keys to discharge the excess current Connect the reset box on the secondary connector of the lock BAT or 2 Power up the reset box with a 9V battery The keypad beep...

Page 11: ...IU_Pulse_01_eng 11 of 12 User instructions Pulse NOTES ...

Page 12: ...olled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Contacts GLOBAL HEADQUARTERS USA HEADQUARTERS SPAIN HEADQUARTERS Tecnosicurezza SpA Tecnosicurezza Inc Tecnosicurezza Sa Via Cesare Battisti 276 50 Thomas Lane C Menor 4 Nave 10 37057 San Giovanni Lupatoto Verona Versailles KY 40383 Pol Ind La Mina ...

Reviews: