IU_Pulse_01_eng
5 of 12
User instructions
Pulse
General information
Using the keypad
To start a time delay counting (if programmed), enter an opening
combination: LED flashes every 2s, indicating the counting.
Press any key to stop the time delay counting.
The opening window is indicated by a flashing and a beep alternating at
1s intervals.
The led remains on if the system is in programming mode.
2 short beeps are produced if an operation/code is correct.
A long beep is produced if an operation/code is incorrect.
If an incorrect operation is performed, wait 5 seconds until the led switches off and try again.
Pre-setup & Configurations
In pre-setup mode, press 1 to open the lock and activate the silent alarm. It’s possible to open
also by inputing 555555 code, in this case the silent alarm is activated by increasing the last
digit by one number of the code (555556).
In pre-setup mode, programming can be performed through a Dallas key or by selecting one of
the following 4 preloaded configurations:
No. configuration
Maximum number of users
Dual code
0
2
No
1
9
No
2
2
Si
3
9
Si
Note
: this programming procedure is not valid for EM6050 locks.
Silent alarm option can be activated in pre-setup mode thanks to a setup Dallas key, or by simply
connecting an alarm interface to the lock and entering an opening code.
Select a keypad configuration (only in pre-setup status)
Hold press the 2 key for few seconds, enter the code 555555 and select the desired
configuration number.
At the end of the configuration only the Manager is installed, with code 123456.
If all users are blocked and only the manager is enabled, time delay and dual code (if
programmed) are not available.