U S E R   I N S T R U C T I O N S  

 

Summary of Contents for T6530/DL

Page 1: ...U S E R I N S T R U C T I O N S ...

Page 2: ...rk requirements Lock bolt operations only allowed as described into the drawing and max load should not exceed 1KN Important Modifications to the lock including lock bolt attachments are not allowed and will void the manufacturer s warranty and Standards approvals No through holes on the safe door are allowed within the lock body area beside the spindle cable hole Lock body area should be protecte...

Page 3: ... penalty two consecutive wrong codes will start it again Additional features TD override user 9 When TD active user 9 always override TD in dual mode Basic Input Output features If standard I O is activated silent alarm 1 on combination last digit will trigger an alarm output signal and disable input features are active through additional 4 wires on board connector Recommandations It is strongly r...

Page 4: ...e minutes lock blocking During this period the light flashes every 10 seconds and any key pressed will produce a long signal After expiration the entry of 2 two more invalid codes will restart the 5 minutes blocking period Change code Press and hold key 0 until double signal Enter the old code double signal Enter the new code double signal Repeat the new code double signal Note In case of errors l...

Page 5: ...ht remains switched on during the following actions Enter the main code Enter time delay value 2 digits from 00 to 99 minutes and open window value 2 digits from 01 to 19 minutes double signal o For instance if you want to program 26 minutes delay and 12 minutes open window enter 2612 Confirm time delay value and open window value double signal Note Time delay value can be increased in every momen...

Page 6: ...s literature indicates that it should not be disposed with other wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Certified ISO 9001 2000 TECNOSICUREZZA s r l Via Cesare Battisti 276 37057...