background image

 

 

IU_BasicLine_01_eng 

 

                                    

LOCK FEATURES 

 

Codes 

 

One  Manager

:  can  open,  changes  his  code,  manage  users,  program  time  delay,  audit 

users and lock. 

User

: can open and change their own codes. 

New codes are rejected when less than 2 digits are different from existing codes. 

 

Time Delay 

Time delay programmable from 0 (no time delay) to 99 minutes. Open window from 1 to 19 
minutes.  
During time delay enabled LED flashes at two seconds intervals. Open window is indicated 
by LED then buzzer at 1 seconds intervals alternately (once LED, once beep). 

 

Battery low warning 

If battery low (<6V) during motor activation, multiple beeps. 

 

Time penalty 

When entering code, a time penalty of 5 minutes will be started after the 4th consecutive 
wrong code entered. During time penalty, LED flashes at 10s interval, no access possible 
to lock. 
Any key pressed during time penalty emits a long beep. 
After time penalty, two consecutive wrong codes will start it again. 

 

Additional features 

 

TD override user #9 – When TD active, user #9 always override TD in “dual mode”. 
Basic Input/Output features – If standard I/O is activated, silent alarm (+1 on combination 
last digit will trigger an alarm output signal) and disable input features are active through 
additional 4-wires on-board connector. 

 

Recommandations 

  It is strongly recommended to immediately change the factory codes 

  For security reasons, do not chose codes which could be easy to guess (e.g. 1 2 3 

4 5 6) 

  For your new code, do not use any personal data like birthdays or any other data, 

that could be derived by knowledge of your person. 

  After code changing, the lock must be tested several times with door in open state. 

  Do not open the lock case, otherwise you compromise the function of the lock and 

warranty will be void. 

  In  order  to  prevent  any  possibility  that  the  code  become  public  or  known  by 

unauthorized  persons  we  strongly  recommend  to  store  any  data  and/or  code  in  a 
safety place, where only its rightful owner can access. 

 

 

Summary of Contents for T6530/DL

Page 1: ...U S E R I N S T R U C T I O N S ...

Page 2: ...rk requirements Lock bolt operations only allowed as described into the drawing and max load should not exceed 1KN Important Modifications to the lock including lock bolt attachments are not allowed and will void the manufacturer s warranty and Standards approvals No through holes on the safe door are allowed within the lock body area beside the spindle cable hole Lock body area should be protecte...

Page 3: ... penalty two consecutive wrong codes will start it again Additional features TD override user 9 When TD active user 9 always override TD in dual mode Basic Input Output features If standard I O is activated silent alarm 1 on combination last digit will trigger an alarm output signal and disable input features are active through additional 4 wires on board connector Recommandations It is strongly r...

Page 4: ...e minutes lock blocking During this period the light flashes every 10 seconds and any key pressed will produce a long signal After expiration the entry of 2 two more invalid codes will restart the 5 minutes blocking period Change code Press and hold key 0 until double signal Enter the old code double signal Enter the new code double signal Repeat the new code double signal Note In case of errors l...

Page 5: ...ht remains switched on during the following actions Enter the main code Enter time delay value 2 digits from 00 to 99 minutes and open window value 2 digits from 01 to 19 minutes double signal o For instance if you want to program 26 minutes delay and 12 minutes open window enter 2612 Confirm time delay value and open window value double signal Note Time delay value can be increased in every momen...

Page 6: ...s literature indicates that it should not be disposed with other wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Certified ISO 9001 2000 TECNOSICUREZZA s r l Via Cesare Battisti 276 37057...