II_T9355/IP_07_eng
Page 1 of 2
T9355/IP: Input/output interface with ethernet port
T9355/IP
includes:
Plastic box
Alarm signals terminals
Ethernet port
Reset button
Keypad/lock connectors
Jumpers NC/NO
For indoor use only.
RS485 PROTOCOL
1. GND
2. RS485 +
3. RS485 -
4. RS485 BUSY
OUTPUTS *
Dry contacts
Normally open/closed
Max 30Vdc
, 1A
Max 60Vdc
, 300mA
Max 125Vac
≂
, 500mA
5. OUTPUT 1 (Silent alarm)
6. OUTPUT 1 (Silent alarm)
7. OUTPUT 2 (Penalty)
8. OUTPUT 2 (Penalty)
INPUT *
Not isolated
Active low
Short circuit between INPUT and GND to activate the signal.
(do not power the Input)
Max 50Vdc
, 20mA
Vil Max= 0,5Vdc Vih Min= 3,0Vdc
9. GND (Remote block)
10. INPUT 1 (Remote block)
11. GND (Remotely managed)
12. INPUT 2 (Rem. managed)
VDC OUTPUT
9Vdc OUT, max 100mA
13. GND
14. 9V OUT+
POWER SUPPLY
12Vdc-24Vdc (1A)
15. GND
16. PWR IN +
* Inputs and outputs can be changed by the TechMaster setup software. The
values shown inside the brackets must be considered just as factory values.
T
ER
M
IN
AT
IO
N
R
ESI
ST
O
R
4
8
5
ETHERNET
N
O
/N
C
N
O
/N
C
RESET
BUTTON
KEYPAD
& LOCK