The ventilation unit is calibrated for connection to the single-phase AC mains supply 230 V / 50 Hz
using 12 VDC transformer. To facilitate cable routing, the ventilation unit comes with a pre-wired
power cord and a plug. Connect the ventilation unit to the mains through the circuit breaker with
integrated magnetic stripe in the wiring system.
CONNECTION OF THE UNIT IN SERIES
When the ventilation units are connected in series, all the connected units are controlled to the first
unit and a common remote control. To connect the ventilation units in series, connect the socket of
the mounting plate output contact of the first ventilation unit with the outlet of the input contact of
the second plate of the ventilation unit assembly.
Now connect the second unit to the third unit in the same way; up to 10 ventilation units can be
connected in series.
Unplug the power cable while connecting the second, third, etc. units.
CONNECTING SEVERAL UNITS IN SERIES (REAR VIEW)
CONNECTING TO THE MAINS
DISCONNECT THE VENTILATION UNIT FROM THE POWER SUPPLY BEFORE ANY
ELECTRICAL INSTALLATION OPERATION. CONNECT THE VENTILATION UNIT TO AN
OUTLET PROPERLY INSTALLED WITH TERMINAL GROUND. DO NOT MAKE ANY CHANGE
TO THE INTERNAL CONNECTIONS: IT WOULD CAUSE THE LOSS OF WARRANTY
22