background image

Accessories for

                       Air Conditioning

     Ventilation

                        Solutions 

    

Air Curtains and

                       Accessories

 

 Accessories

                     For Heating

Instruments &

                         Tools

Multi - Zone

Air Control System

22

TECHNICAL FEATURES 

CODE

DIMENSIONS (mm)

B

C

Ø 

TOTAL AIR 200P EVO PLUS

900

500

313

150

TOTAL AIR 300P EVO PLUS

900

500

313

150

TOTAL AIR 200P EVO PLUS

900

500

313

150

TOTAL AIR 300P EVO PLUS

900

500

313

150

A

B

Ø

C

Summary of Contents for TOTAL AIR 200P EVO PLUS

Page 1: ...9 Vittorio Veneto Treviso Italia Tel 39 0438 500044 Fax 39 0438 501516 Numero Verde 800 904474 only for Italy email info tecnosystemi com C F P IVA R I TV IT02535780247 Cap Soc 5 000 000 00 i v www te...

Page 2: ...rcorso a bassa perdita di carico portando il consumo di energia elettrica al minimo possibile naturalmente questa funzione ha senso solo se le condizioni esterne lo consentono INTRODUZIONE REQUISITI D...

Page 3: ...per le apparecchiature elettriche PRECAUZIONI OPERATIVE DI SICUREZZA Non lavare il recuperatore di calore con acqua Proteggere le parti elettriche del ventilatore dall ingresso di acqua Staccare il re...

Page 4: ...cambio d aria evitando nello stesso tempo la dispersione della temperatura interna Il principio del recuperatore e quello di immettere in modo continuo aria fresca e pulita prelevata dall esterno e co...

Page 5: ...resa dell aria viziata presente nei vari locali In ogni caso se la temperatura esterna si discosta troppo dal valore desiderato in ambiente anche se migliorativa la modalit Free Cooilng non avviene qu...

Page 6: ...6 DIMENSIONI MODELLO DIMENSIONI mm A B C TOTAL AIR 200P EVO PLUS 900 500 313 150 TOTAL AIR 300P EVO PLUS 900 500 313 150 TOTAL AIR 200P EVO PLUS 900 500 313 150 TOTAL AIR 300P EVO PLUS 900 500 313 15...

Page 7: ...mento richiesto dal recuperatore essenzialmente quello di potenza La potenza non altro che l alimentazione 230V 50Hz 1Ph Sulla linea di alimentazione bene prevedere a monte sia un sezionatore sia un p...

Page 8: ...Sistemi 8 COLLEGAMENTO PANNELLO DI CONTROLLO...

Page 9: ...Ogni macchina dotata di 4 collarini 1 di aspirazione e 1 di espulsione su due lati realizzati per ricevere I condotti canalizzati dell impianto di ventilazione Qualora la posizione dei tubi canalizzat...

Page 10: ...con distanza di apertura dei contatti 3 mm Durante il normale funzionamento della macchina si pu avere la formazione di condensa la quale deve uscire dal recuperatore per evitare problemi alle parti...

Page 11: ...TTIMANA 11 ALLARME FILTRI SPORCHI 12 CAMPO SECONDARIO Se compare la scritta CN sul display significa che non c comunicazione con il controllo elettro nico al quale connesso All accensione del terminal...

Page 12: ...rrisponde all accensione dell icona Pressione lunga 3 s accesso al menu impostazione orologio fasce orarie Selezionare con la manopola tra le seguenti opzioni CLOCK impostazione data ora cor rente una...

Page 13: ...13 Sistemi IMPOSTAZIONE FASCE ORARIE...

Page 14: ...Sistemi 14 IMPOSTAZIONE FASCE ORARIE...

Page 15: ...15 Sistemi IMPOSTAZIONE FASCE ORARIE...

Page 16: ...i 6 mesi che si rende necessaria al fine di ottimizzare il loro funzionamento L accesso ai filtri e al pacco di scambio facilmente estraibili per agevolarne la pulizia avviene tramite il pannello di i...

Page 17: ...IVA R I TV IT02535780247 Cap Soc 5 000 000 00 i v www tecnosystemi com Accessories for Air Conditioning Ventilation Solutions Air Curtains and Accessories Instruments Tools Multi Zone Air Control Syst...

Page 18: ...allowed to enter directly into the environment along a path with low flow loss bringing electricity consumption to the minimum possible of course this function is suitable only if external conditions...

Page 19: ...the recuperator follow the specific safety regulations for electrical equipment SAFETY OPERATING PRECAUTIONS Do not wash the recuperator with water Protect the electrical parts of the fan from water D...

Page 20: ...ttings and adapt to those environments in which it is necessary to exchange air though avoid the dispersion of the internal temperature The principle of the recuperator is to continuously introduce fr...

Page 21: ...er than the recovery temperature of the stale air in the various rooms In any case if the outside temperature deviates too much from the desired indoor temperature the Free Cooling mode is not activat...

Page 22: ...ents Tools Multi Zone Air Control System 22 TECHNICAL FEATURES CODE DIMENSIONS mm A B C TOTAL AIR 200P EVO PLUS 900 500 313 150 TOTAL AIR 300P EVO PLUS 900 500 313 150 TOTAL AIR 200P EVO PLUS 900 500...

Page 23: ...R PUR 300 The recuperator must be connected to a power source Specifically it requires a 230V 50Hz 1Ph power supply It is advisable to equip the upstream of the supply line with a disconnect switch an...

Page 24: ...Tools Multi Zone Air Control System 24 CONTROL PANEL CONNECTION Power board on units Power board Wall control board Wall control detail of the connection board to the display particular clamp for con...

Page 25: ...with 4 collars 1 suction and 1 expulsion collar on both sides designed to receive the ducts of the ventilation system If the position of the ducted pipes is exposed to water splashes or jets appropri...

Page 26: ...of 3 mm During standard machine operation condensation may form and be released from the recuperator to avoid problems with the electrical parts For this reason the appliance is set up with two conde...

Page 27: ...NDS 9 CURRENT TIME BANDS 10 DAY OF THE WEEK 11 DIRTY FILTER ALARM 12 SECONDARY FIELD If the word CN appears on the display it means that there is no communication with the electron ic control When the...

Page 28: ...or automatic operation Auto CLOCK Short press enable disable the time schedule When the icon is lit the system is activated Long press 3 seconds access to the clock time settings menu Select with the...

Page 29: ...29 Ventilation Solutions Accessories For Heating Instruments Tools Multi Zone Air Control System TIME BAND SETTING...

Page 30: ...Ventilation Solutions Accessories For Heating Instruments Tools Multi Zone Air Control System 30 TIME BAND SETTING...

Page 31: ...31 Ventilation Solutions Accessories For Heating Instruments Tools Multi Zone Air Control System TIME BAND SETTING...

Page 32: ...re periodic maintenance every 6 months which is necessary in order to optimize their operation Access to filters and the exchange pack which can be easily removed to facilitate cleaning takes place th...

Page 33: ...33 Ventilation Solutions Accessories For Heating Instruments Tools Multi Zone Air Control System NOTE...

Page 34: ...warranty covers defects in materials and manufacturing defects and refers to the supply of spare parts of any components featuring defects without any compensation interest or claim for damages The wa...

Reviews: