ENGLISH
ATA Energy Storage System MM
51
User’s manual
13
Pre-setting voltage back to
battery mode when selecting
“Solar first” or “SBU priority”
in program 01.
48V
49V
50V
(default)
51V
52V
53V
54V
55V
56V
57V
58V
Battery fully charged
16
Charger source priority:
To configure charger source
priority
If this inverter/charger is working in Line, Standby or Fault mode,
charger source can be programmed as below:
Solar first
Solar energy will charge battery as
first priority.
Utility will charge battery only when
solar energy is not available.
Utility first
Utility will charge battery as first
priority.
Solar energy will charge battery only
when utility power is not available.
Solar and Utility
Solar energy and utility will charge
battery at the same time.
Only Solar
(default)
Solar energy will be the only charger
source no matter utility is available or
not.
If this inverter/charger is working in Battery mode or Power
saving mode, only solar energy can charge battery. Solar energy
will charge battery if it's available and sufficient.
Summary of Contents for ATA 4.0 MM
Page 2: ......
Page 64: ...ENGLISH User s manual 58 ATA Energy Storage System MM...
Page 123: ......
Page 124: ...TECNOWARE s r l www tecnoware com...