Ups Pro 

7

 

User’s manual 

 

5

 

Electrical Installation and First Start Up 

We advise you to follow the steps below explained for greater safety: 

1.

 

Switch off all the devices (Computer or other electronic devices) that need to be supplied by the UPS. 

2.

 

Connect  the  UPS  Input  power  cable  to  the  AC  line  outlet. 

It  is  mandatory  to  ground  the  AC  line  outlet 

according  to  the  Safety  Standards

.  Carefully  check  the  grounding,  make  sure  that  the  utility  power  is 

available, and that its range falls within the UPS specifications (refer to the “Specifications” chapter). 

3.

 

Press the 

ON/OFF

 button on the front panel: the UPS emits a brief acoustic signal, turns the LCD display on, 

and  performs  a 

functioning  SELF-TEST

.  Leave  the  UPS  in  Normal  mode  for  at  least  4  hours  in  order  to 

completely recharge the batteries. 

4.

 

Switch the UPS off (by pressing again the ON/OFF button). 

5.

 

Connect  the  devices  to be supplied to the UPS outputs. Be sure all the devices have the main switch in ON 
position. 

6.

 

Turn  on  the  UPS  again.  Check  that  it  starts  working  correctly  and  it  doesn’t  signal

 

any  sort  of  anomaly. 

Moreover  be  sure  that  all  the  devices  connected  to  the  UPS  outputs  are  working  correctly.  By  LCD  display 
check if the Output load percentage is less than 100%; otherwise it is necessary to remove part of the Output 
load.  

7.

 

Simulate a black-out by removing the AC Input line. The UPS starts working in 

Battery mode

. Moreover the 

UPS emits a brief acoustic signal every 10 seconds. 

8.

 

Be sure that all the devices connected to the UPS outputs are working correctly and the UPS doesn’t signal

 

any sort of anomaly. 

9.

 

Restore the AC Input line: after few seconds the UPS turns back in Normal mode. 

 

Before using Ups Pro normally, leave it in Normal mode in order to charge the batteries completely as specified at 
point 3. The batteries reach the 90% of their capacity after about 4 hours of recharge. 

 

 

It is compulsory to ground/earth the UPS according to the Safety Standards. 

Risk  of  electric  shock  at  the  Output  lines  if  the  UPS  is  ON,  even  when  the  UPS  is  not 
connected to AC utility line. 

Risk  of  electric  shock  at  the  Output  lines  while  the  unit  is  connected  to  the  AC  utility 
line. 

Risk of electric shock: do not remove the cover. The UPS contains internal parts, which 
are at a high Voltage and are potentially dangerous, capable of causing injury or death 
by electric shock. 

There  are  no  internal  parts  in  the  UPS  that  are  user  serviceable.  Any  repair  or 
maintenance  work  must  be  performed  exclusively  by  qualified  technical  personnel 
authorized  by  TECNOWARE.  TECNOWARE  declines  any  responsibility  if  this  warning  is 
disregarded. 

Disregard for these warnings may lead to a risk of electric shock to operators. 

 

Summary of Contents for Ups Pro

Page 1: ...Uninterruptible Power Supply Ups Pro User s manual Manuale utente...

Page 2: ......

Page 3: ...racteristics 10 9 Maintenance 11 9 1 UPS Cleaning 11 9 2 Battery 11 9 3 Operator Safety 11 10 Troubleshooting 12 Conformity to the European Directives 13 Product Disposal 13 Lead Batteries 13 Copyrigh...

Page 4: ...Funzionamento 21 6 1 Modo Normale 21 6 2 Modo Batteria 21 6 3 Fine Autonomia e Riaccensione Automatica 21 6 4 Controllo del Carico 21 6 5 Segnalazioni di Guasto 22 7 Interfacce di Comunicazione 22 8...

Page 5: ...ed to the batteries they will remain powered and therefore dangerous even after the UPS has been disconnected from AC power mains Before any repair or maintenance work disconnect the batteries by remo...

Page 6: ...B interface which can be used to notify a power failure or a low battery condition directly to a computer this makes it possible to automatically save your data during an extended black out Read this...

Page 7: ...design and easy to use 3 Receipt and site selection Carefully remove the UPS from its packaging and carry out a meticulous inspection We recommend keeping the original packaging in a secure place in c...

Page 8: ...tus alarm conditions and measurements Front panel shown below consists of two parts 1 LCD display provides information about input and output voltage battery level percentage load level percentage fun...

Page 9: ...nt is on 25 50 2 segments are on 50 75 3 segments are on 75 100 all the 4 segments are on 4 LOAD LEVEL is a four segment light bar This bar indicates the Output Load percentage as explained below 0 25...

Page 10: ...B connector it is the communication USB port 5 Input circuit braker electrical specification max current 7A voltage 250 V The ONLY FILTERED Output receptacle 3 protects only the devices connected from...

Page 11: ...otherwise it is necessary to remove part of the Output load 7 Simulate a black out by removing the AC Input line The UPS starts working in Battery mode Moreover the UPS emits a brief acoustic signal e...

Page 12: ...g of an icon on the display and an acoustic signal every 10 seconds 6 3 Low Battery and Automatic Restart In Battery mode Ups Pro indicates the Low Battery condition whenever the battery reaches a cha...

Page 13: ...t connect a load greater than rated value to the UPS see POWER specifications in the chapter Technical Characteristics as this may damage the unit In this case the warranty is void 6 5 Fault Condition...

Page 14: ...EI EN 62040 1 2008 Low Voltage Directive CEI EN 62040 2 2006 EMC Directive Efficiency 96 Battery Type Lead acid sealed free maintenance Number of batteries 1 Nominal Battery Voltage 24 Vdc Battery Spe...

Page 15: ...ribed in the chapter 5 before using it again Please keep in mind that the batteries must be recharged at least once a month Take in mind that batteries are recharged automatically if the UPS works in...

Page 16: ...cable red colour from the positive pole of the battery ANOMALY POSSIBLE CAUSE ACTION TO SOLVE The UPS does not turn on ON OFF button Press the ON OFF button Batteries are flat Recharge the batteries f...

Page 17: ...waste but must be treated as a separate waste Any violation is indictable with financial sanctions as per in force regulations An incorrect waste disposal or an improper use of the same or of any par...

Page 18: ...gato dalla rete elettrica le parti interne sono ancora in tensione essendo collegate alle batterie e quindi pericolose Prima di effettuare qualsiasi tipo di riparazione o manutenzione scollegare le ba...

Page 19: ...di utilizzare Ups Pro perch contiene importanti avvisi di sicurezza per l operatore ed utili consigli per un corretto impiego Questo manuale una guida per installare e utilizzare correttamente l UPS...

Page 20: ...nnotarli sulla bolla di accompagnamento merce e contattare subito il fornitore Si consiglia di conservare l imballo originale in luogo sicuro nell eventualit futura che l UPS dovesse essere spedito pe...

Page 21: ...ure Il pannello frontale mostrato nella figura 1 costituito da 2 parti 1 Un display LCD che fornisce i valori della tensione d ingresso e d uscita la percentuale di carica delle batterie la percentual...

Page 22: ...ritto sotto 0 25 acceso solo 1 segmento 25 50 sono accesi 2 segmenti 50 75 sono accesi 3 segmenti 75 100 sono accesi tutti e 4 i segmenti 4 LOAD LEVEL costituita da 4 segmenti che si illuminano in fun...

Page 23: ...are per alimentare carichi NON critici 4 Interfaccia di Comunicazione connettore USB la porta di comunicazione USB 5 Fusibile d Ingresso Termico caratteristiche elettriche corrente massima 7A tensione...

Page 24: ...e assicurandosi che il valore sia inferiore al 100 altrimenti necessario rimuovere parte del carico in Uscita 7 Simulare un black out togliendo la Tensione di Rete elettrica in Ingresso L UPS passa a...

Page 25: ...ento in modo Batteria le batterie sono scariche al punto da garantire soltanto alcuni minuti di autonomia L UPS avvisa l utente della condizione di Fine Autonomia con l accensione dell apposita icona...

Page 26: ...caso di guasto l UPS non fornisce potenza in uscita e quindi si spengono tutti i dispositivi alimentati 7 Interfacce di Comunicazione L UPS dotato dell interfaccia USB utilizzabile come porta di comun...

Page 27: ...c Certificazioni CE Norme di riferimento CEI EN 62040 1 2008 Direttiva Bassa Tensione CEI EN 62040 2 2006 Direttiva EMC Rendimento 96 Tipo Batterie Piombo acido sigillate senza manutenzione Numero di...

Page 28: ...rlo normalmente svolgere la procedura di Prima Accensione descritta nell omonimo capitolo di questo manuale Tenere comunque presente che le batterie vanno ricaricate almeno 1 volta al mese Si ricorda...

Page 29: ...vo della batteria a cui collegato ANOMALIA POSSIBILE CAUSA AZIONI PER RISOLVERE L UPS non si accende Pulsante ON OFF Premere il pulsante ON OFF Batterie scariche Ricaricare le batterie per almeno 6 or...

Page 30: ...come rifiuto urbano ma deve esserlo tramite raccolta separata qualsiasi violazione punita con sanzioni pecuniarie ai sensi delle vigenti norme Lo smaltimento non corretto del prodotto o l uso impropri...

Page 31: ......

Page 32: ...TECNOWARE s r l www tecnoware com...

Reviews: