EV Inverter Operating Manual
___________________________________________________________________________
TECO
– Westinghouse Motor Company 12
Section 7
-
Fuse Types and Ratings
Inverter input fuses are provided for safely disconnecting the inverter from the input power in the
event of
a failure in the inverter‘s power circuitry. The inverter‘s electronic protection circuitry is
designed to clear inverter output short circuits and ground faults without blowing the inverter input
fuses. The table below shows the EV input fuse ratings; To protect the inverter most effectively,
use fuses with current-limiting capabilities.
RK5 and CC/T type fuse ratings for the EV AC Drive series
115V class (1Ø)
JNEV-
HP
KW KVA
100% CONT
Output AMPS
Max.RK5
FUSE
Rating(A)
Max.CC or T
FUSE
Rating(A)
1P2-H1
0.25
0.2
0.53
1.7
10
20
1P5-H1
0.5
0.4
0.88
3.1
15
30
101-H1
1
0.75
1.6
4.2
20
40
230V class (1Ø)
JNEV-
HP
KW KVA
100% CONT
Output AMPS
Max.RK5
FUSE
Rating(A)
Max.CC or T
FUSE
Rating(A)
2P2-H1
0.25
0.2
0.53
1.7
8
15
2P5-H1
0.5
0.4
0.88
3.1
10
20
201-H1
1
0.75
1.6
4.2
15
30
202-H1
2
1.5
2.9
7.5
20
40
203-H1
3
2.2
4.0
10.5
25
50
230V class (3Ø)
JNEV-
HP
KW KVA
100% CONT
Output AMPS
(A)
Max.RK5
FUSE
Rating(A)
Max.CC or T
FUSE
Rating(A)
2P2-H3
0.25
0.2
0.53
1.7
5
8
2P5-H3
0.5
0.4
0.88
3.1
8
10
201-H3
1
0.75
1.6
4.2
12
15
202-H3
2
1.5
2.9
7.5
15
20
203-H3
3
2.2
4.0
10.5
20
30
460V class (3Ø)
JNEV-
HP
KW KVA
100% CONT
Output AMPS
(A)
Max.RK5
FUSE
Rating(A)
Max.CC or T
FUSE
Rating(A)
401-H3
1
0.75
1.7
2.3
6
10
402-H3
2
1.5
2.9
3.8
10
15
403-H3
3
2.2
4.0
5.2
10
20
Note: Fuse ratings are based upon 300V fuses for 120V inverters, 300V fuses for
230V inverters, and 500V for 460V inverters.