EV Inverter Operating Manual
___________________________________________________________________________
TECO
– Westinghouse Motor Company 19
F21
Multi-function output RY1
000 Run
000
001
Frequency reached
(Set frequency ±
F23
)
002
Frequency is within the
range set by (
F22±F23
)
003
Frequency detection
(
>F22
)
004
Frequency detection
(
<F22
)
005 Fault terminal
006 Auto reset and restart
007 Momentary power loss
008 Emergency stop (E.S.)
009 Base block (b.b.)
010 Motor overload protection
011 Inverter overload protection
012
Not used
013 Power on
014 Communication error
015
Output current
detection(
>F24
)
F22
Preset output frequency target
(
Hz
)
-
00.0
– 200
00.0
Note 1
F23
Target frequency
detection range (±
Hz
)
-
00.0 - 30.0
00.0
Note 1
F24
Output current target value
(
%)
-
000
– 100
000
F25
Output current detection
time(
sec.
)
-
00.0
– 25.5
00.0
F26
Multi-function analog output
type selection
(
0 - 10VDC
)
000 Output frequency
000
Note 1
001 Set frequency
002 Output voltage
003 DC voltage
004 Output current
005 PID feedback signal
F27
Multi-function analog output
gain (
%
)
-
000
– 200
100
Note 1
F28
Preset frequency 1 (Main
frequency setting) (
Hz
)
-
00.0 - 200
05.0
Note 1&2
F29
Preset frequency 2 (
Hz
)
-
00.0 - 200
05.0
Note 1&2
F30
Preset frequency 3 (
Hz
)
-
00.0 - 200
10.0
Note 1&2
F31
Preset frequency 4 (
Hz
)
-
00.0 - 200
20.0
Note 1&2
F32
Preset frequency 5 (
Hz
)
-
00.0 - 200
30.0
Note 1&2
F33
Preset frequency 6 (
Hz
)
-
00.0 - 200
40.0
Note 1&2
F34
Preset frequency 7 (
Hz
)
-
00.0 - 200
50.0
Note 1&2
F35
Preset frequency 8 (
Hz
)
-
00.0
– 200
60.0
Note 1&2
F36
Jog frequency setting (
Hz
)
-
00.0
– 200
05.0
Note 1&2
Summary of Contents for EV INVERTER Series