EV Inverter Operating Manual
___________________________________________________________________________
TECO
– Westinghouse Motor Company 27
Section 11
-
Parameters F (Basic) and C (Advanced) Function Descriptions
F (Basic) Parameter Function Descriptions
F00 Inverter horsepower capacity
F00
Inverter model
F00
Inverter model
1P2
JNEV
1P2
203
JNEV
203
1P5
1P5
401
401
101
101
402
402
2P2
2P2
403
403
2P5
2P5
201
201
202
202
F 0 1 Acceleration time 1 (sec) : 00.1
– 999
F 0 2 Deceleration time 1 (sec) : 00.1
– 999
Formula for acceleration/deceleration time: Denominator is based on the setting of C14
a) Motor rated frequency (Sensorless vector control C14=000)
b) Max output frequency (V/f mode C14=001)
a)
Vector
Set frequency
Set frequency
Accel time = F01 ×
Decel time = F02 ×
F45 (rated frequency) F45 (rated frequency)
b)
V/F
Set frequency
Set frequency
Accel time = F01 ×
Decel time = F02 ×
C17 (Max. output freq.) C17 (Max. output freq.)
F03 Motor rotation direction
000: Forward
001: Reverse
Parameter F04 must be set to 000 for this function to be effective.
F04 Run signal source
000: Keypad
001: External terminal
002: Communication control
1. ) F04=000: inverter is controlled by the keypad.
2. ) F04=001: inverter is controlled by external signals via the I/O terminal, TM2.
3. ) F04=002: inverter is controlled by serial communications.
F05 Frequency signal source
000: UP/Down key on keypad
001: Potentiometer on keypad
002:TM2 input signal (Terminal AIN)
003: Multi-function input terminal UP/DOWN function
004: Frequency set by communication method
( NOTE: When C47=1, the remote keypad has priority)
Summary of Contents for EV INVERTER Series
Page 69: ......