EV Inverter Operating Manual
___________________________________________________________________________
TECO
– Westinghouse Motor Company 30
F10 Status monitoring
display
000: Disable
001: Enable
F10 = 001: Display motor current, voltage, DC bus voltage, and PID feedback along
with frequency. F10 = 000: Display frequency only.
F11 - 15
Selectable Functions for input terminals ( S1-S4& AIN )
000: Forward run
001: Reverse run
002: Preset speed command 1
003: Preset speed command 2
004: Preset speed command 3
005: Jog frequency command
006: External emergency stop (E.S.)
007: Base block (b.b.)
008: Switch to 2nd acceleration / deceleration time
009: Reset
010: Up command
011: Down command
012: Control signal switch
013: Communication mode. Disable / Enable.
014: Acceleration / deceleration prohibit
015: Master / Auxiliary speed switch
016: PID function disable
017: Analog frequency signal input ( terminal AIN)
018:
PID feedback signal (terminal AIN)
019: DC Brake signal
1.) S1 - AIN on TM2 are the multi-function input terminals which can be set to the above 19 functions.
2.) F11 - F15 function descriptions:
F11 - F15=000 / 001: Forward/ Reverse
When the Forward command is ON, the inverter runs forward; when OFF the inverter stops.
F11 is the factory default Forward command. When the Reverse command is ON, the inverter
runs in reverse; when OFF the inverter stops. F12 is the factory default Reverse command.
N
O T E: I f b o t h f o r w a rd a n d re v e rs e c o m m a n d a r e O N a t t h e s a m e t i m e t h e
i n v e rt e r w i l l a c t i v a t e St o p m o d e .
F11 - F15=002 - 004: Preset speed commands 1 - 3
When the run signal is applied and any of the selected external multi-function input terminals
are ON, the inverter will run at one of 8 preset speeds depending on the combined state of all
the multi-function input terminals. The corresponding speeds are programmed by parameters
F28 to F36 as shown in the table on the next page.
F11 - F15=005: Jog frequency command
When a run signal is applied and the selected external multi-function input terminal is
configured for
Jog
speed and is active (On), the inverter will run at the frequency programmed
in the F36 setting. (See table on next page)
NOTE: Priority of the frequencies: Jog > Preset Speed