EV Inverter Operating Manual
___________________________________________________________________________
TECO
– Westinghouse Motor Company 61
P
ro
tec
ti
ve
Fu
n
ctio
n
s
Over load protection
Inverter rated current 150%/1min
International
conformity
UL / CE
Over voltage
230V Class: DC voltage >400V 460V Class: DC voltage >800V
Under voltage
230V Class: DC voltage <190V 460V Class: DC voltage <380V
Instantaneous power
loss restart
Set to enable or disable
Stall prevention
ACC / DEC / Operation stall prevention and stall prevention level.
Output terminal short
circuit
Electronic circuit protection
Other faults
Electronic circuit protection
Other functions
Over current, over voltage, under voltage, over load, instantaneous power
loss restart, ACC / DEC / Operation stall prevention, output terminal short
circuit, grounding error, reverse limit, directly start on power up and fault
reset limit.
Note1: The setting resolution above 100Hz is 1Hz when controlled by keypad, and 0.01Hz
when controlled using a computer (PC) or programmable controller (PLC).
N
ote 2: EV-1P2 - 101-H1, 2P2 -201-H1/H3,
and
401- 403-H3 type (Carrier frequency =10KHz) with
option filter complies with EN61800-3 first environment restricted distribution.
EV-202- 203-H1/H3 type (Carrier frequency =10KHz) with option filter complies with
EN61800-3 first environment unrestricted distribution.
EV-2P2-201-H1F type (Carrier frequency =10KHz) with
built-in
filter complies with EN61800-3
first environment unrestricted distribution.
(IP65) EV-2P2-403-H1(3)FN4(S) series & EV- 401- 403-H3F type (Carrier frequency=10KHz)
With built
-in f
ilter & EV-202-203-H1F type (Carrier frequency =10KHz) complies with
EN61800-3 first environment restricted distribution.
Summary of Contents for EV INVERTER Series