6.5 MULTI-FUNCTION INPUT SELECTION
Sn-04, Sn-15 to -19, bn-09
Response to constant input is selected by the setting of Sn-15 to -19.
(Example 1) 2-step speed operation by analog reference. (Set Sn-04 to 0000)
Keypad Operation
Digital Operator Display
DSPL
DATA
ENTER
-
Constant Setting
Terminal Sn-
Set
Value
Factory
Setting
Name
5 15 3 3
Multi-step speed
reference 1
6 16 4 4
Multi-step speed
reference 2
7
17
6
6
Jog frequency *
8 18 8 8
External baseblock
command
16 19 0
0
Auxiliary
frequency
* If jog frequency reference and multi-step speed reference
(1, 2) are turned ON simultaneously, jog frequency reference has priority.
─
─
31
MASTER
SPEED
OUTPUT
FREQUENC
AUXILIARY
FREQUENC
TIME
CLOSE
TERMINA
OPEN
FWD RUN
COMMAND
MULTI-STEP SPEED
REFERENCE
MULTI-STEP SPEED
REFERENCE
JOG FREQUENCY
○
1
○
5
○
6
○
7
CLOS
OPEN
OPEN
OPEN
OPEN