*1 Differs according to inverter capacity.
*2 Initialization (Sn-03 = 1110, 1111)
After depressing the ENTER key, input the initial value of An- , bn- , Sn- , Cn- , (except Sn-01,Sn-02) into NV-RAM.
When the value is written in without an error, is displayed. When the value is written in with an error, is displayed. The values of
Sn-15 to -18 differ as follows between initializations with Sn-03 = 1110 and with Sn-03 = 1111.
Multi-function
Terminal
1110
(2 Wire Sequence)
1111
(3 Wire Sequence)
Terminal 5 (Sn-15)
3* (Multi-step speed command 1)
0 (FWD/REV run select)
Terminal 6 (Sn-16)
4* (Multi-step speed command 2)
3 (Multi-step speed reference 1)
Terminal 7 (Sn-17)
6* (Jog frequency reference) 4
(Multi-step
speed reference 2)
Terminal 8 (Sn-18)
8* (External baseblock command)
6 (Jog frequency reference)
* Values have been factory-set.
*3 Setting of Sn-05 4th digit and Sn-09 2nd digit.
Sn-05
4th Digit
Sn-09
2nd Digit
Description
0 0
Output analog signal proportional to inverter output frequency.
(Max. frequency/100%)
1 0
Output analog signal proportional to inverter output current.
(Rated current/100%)
0 1
Output analog signal proportional to inverter output voltage reference.
(Cn-01/100%)
1 1
Output analog signal proportional to inverter output power.
(Max. applicable motor capacity/100%)
*4 Effective only for inverter models of capacity 230V 40HP (30kW) or more, 460V 75HP (55kW) or more.
--60--