3-38
Function
Parameter
No.
Name
LCD display
(English)
Description
Factory
Setting
Ref.
Page
Sn-68
Control selection
Sn-68
=
0000
Control selection
The very parameter is available for 30.15
and later version
–––1: Output phase lose protection
function valid
–––0: Output phase lose protection
function invalid
––1–: Reserved
––0–: Reserved
(Bit3 function is available for 30.16 and
later version)
–1––: ±10V analog voltage input function is
valid
–0––: ±10V analog voltage input function is
invalid
1–––: Frequency Up/Down hold function
valid
0–––: Frequency Up/Down hold function
invalid
* only 4P101C01301 control base board
supports input of ±10V analog voltage.
0
3-73
Operation
Control
Mode
Selection
Sn-69
*3
Torque Detection
2 Selection
Sn-69= 0
Tq.Detect Invalid
0 : Torque detection function 2 is not
effective.
1 : Overtorque is detected only at
frequency agree. Continue operation
after detection.
2 : Overtorque is detected only at
frequency agree. Stop operation after
detection.
3 : Overtorque is detected during running
(Accel.,Decel. included). Continue
operation after detection.
4 : Overtorque is detected during running
(Accel., Decel included). Stop operation
after detection.
5 : Undertorque is detected only at
frequency agree. Continue operation
after detection.
6 : Undertorque is detected only at
frequency agree. Stop operation after
detection.
7 : Undertorque is detected during running
(Accel.,Decel. included). Continue
operation after detection.
8 : Overtorque is detected during running
(Accel., Decel included). Stop operation
after detection.
0
3-47