1-5
(B)
For 230V : 3-10HP, 460V : 3-10HP
y
MA7200-2003-N1
y
MA7200-4003-N1
y
MA7200-2005-N1
y
MA7200-4005-N1
y
MA7200-2007-N1
y
MA7200-4007-N1
y
MA7200-2010-N1
y
MA7200-4010-N1
■
Removing the digital operator
Take off the screws in the place a. and b.
Press the lever on the side of the digital operator
in the direction of arrow 1 to unlock the digital
operator.
Disconnect the RS-232 cable connector on the
back side of the LCD digital operator. Lift the
digital operator in the direction of arrow 2 to
remove the digital operator.
1
2
a
b
Front Cover
LCD Digital Operator
■
Removing the front cover
Press the left and right sides of the front cover in
the directions of arrow 1 and lift the bottom of the
cover in the direction of arrow 2 to remove the
front cover.
1
2
1
Front
Cover
c
RS-232
Cable
Connector
■
Mounting the front cover and digital operator
Insert the tab of the upper part of front cover into
the groove of the inverter and press the lower part
of the front cover onto the inverter until the front
cover snaps shut.
Connecting the RS-232 cable connector on the
back side of the LCD digital operator and hook
the digital operator at a on the front cover in the
direction of arrow 1.
Press the digital operator in the direction of arrow
2 until it snaps in the place b and then tighten the
screws in the place c and d. (on the front cover)
1
2
Front
Cover
c
b
a
d
e
Digital
Operator
RS-232
Cable
Connector