4-9
Function
Code No.
Description Range/Code
Factory
Setting
Remarks
04-03
Momentary Power Loss and
Restart
0 : Momentary Power Loss and Restart
disable
1 : Momentary power loss and restart
enable
2 : Momentary power loss and restart
enable while CPU is operating.
(According to the capacity of DC
power)
0
04-04
Momentary Power Loss
Ride-Thru Time (Seconds)
0.0 - 2.0
0.5
04-05 Auto
Restart
Method
0 :
Enable Speed Search
1 : Normal Start
0
04-06 Auto Restart Delay Time (Seconds)
0.0 - 800.0
0.0
04-07 Number of Auto Restart Attempts
0-10
0
04-08 Reset Mode Setting
0 : Enable Reset Only when Run
Command is Off
1 :
Enable Reset when Run
Command is On or Off
0
04-09 Direct Running After Power Up
0 :
Enable Direct running after power
up
1 :
Disable Direct running after power
up
1
04-10 Delay-ON Timer (Seconds)
1.8 ~300.0
1.0
04-11
Kinetic Energy
Back-up Deceleration Time
0.0 :
Disable
0.1~25.0
:
KEB Deceleration Time
0.0
04-12 Lower Limit of Power Voltage Detect 150.0~210.0/300.0~420.0
190.0/380.0
04-13 DC Injection Brake Level (%)@start 0.0~150.0 50.0
04-14
DC Injection Brake Time
(Seconds) @start
0.0~25.5 0.5
04-15
DC Injection Brake Start
Frequency (Hz) @stopped
0.10~10.00 1.50
04-16
DC Injection Brake
Level(%)@Stopped
0.0~150.0 50.0
04-17
DC Injection Brake Time
(Seconds) @stopped
0.0~25.5 0.5
04-18 Braking transistor action level
200V : 320~400
380V : 550~800
200V : 380
380V : 690