4-47
Group 16 LCD Function Parameters
Code Parameters
Setting Range
Default Unit
Control Mode
Attribute
V/F SLV
PM
SLV
16-00
Main Screen
Monitoring
5~43
when using LCD to operate, the monitored item
displays in the first line. (default: frequency command)
16
-
O
O
O
*1*7
16-01
Sub-Screen
Monitoring 1
5~43
when using LCD to operate, the monitored item
displays in the second line. (default: output frequency)
17
-
O
O
O
*1*7
16-02
Sub-Screen
Monitoring 2
5~43
when using LCD to operate, the monitored item
displays in the third line. (default is output current))
18
-
O
O
O
*1*7
16-03 Display Unit
0~39999
Determine the display way and unit of frequency
command
0:Frequency display unit is 0.01Hz
1:Frequency display unit is 0.01%
2:Frequency display unit is RPM.
3~39:Reserved
40~9999:
Users specify the format, Input 0XXXX represents the
display of XXXX at 100%.
10001~19999:
Users specify the format; Input 1XXXX represents the
display of XXX.X at 100%.
20001~29999:
Users specify the format, Input 2XXXX represents the
display of XX.XX at 100%.
30001~39999:
Users specify the format, Input 3XXXX represents the
display of X.XXX at 100%.
0
-
O
O
O
*7
16-04
Engineering
Unit
0:No Unit
1:FPM
2:CFM
3:PSI
4:GPH
5:GPM
6:IN
7:FT
8:/s
9:/m
10:/h
11:°F
12:inW
13:HP
14:m/s
15:MPM
16:CMM
17:W
18:kW
19:m
20:°C
21:RPM
22:Bar
23:Pa
24:kPa
0
-
O
O
O
*7
16-05 LCD Backlight 0~7
5
-
O
O
O
*1*7
16-07
Copy Function
Selection
0:Do not copy parameters
1:Read inverter parameters and save
them to the operator.
2:Write the operator parameters to inverter.
3:Compare parameters of inverter and operator.
0
-
O
O
O
*7
Summary of Contents for E510-201-SH
Page 1: ......
Page 28: ...3 14 b 200V 2HP 1 3PH 200V 3HP 20HP 400V 3HP 25HP IP20 NEMA1 ...
Page 29: ...3 15 c 200V 25HP 400V 30HP d 200V 30HP 40HP 400V 40HP 75HP ...
Page 51: ...3 37 3 5 Standard Wiring 10V AI1 AI2 AGND E P P ...
Page 72: ...4 6 4 1 4 Example of keypad operation Example 1 Modifying parameters ...
Page 74: ...4 8 4 1 5 Operation control ...
Page 206: ...4 140 Acceleration Deceleration calculation of mode 2 ...
Page 316: ...4 250 6 Timer mode 6 FLASH Timer mode 2 7 Timer mode 7 FLASH Timer mode 3 ...
Page 424: ...REVISIONS Date Manual Number Revision May 2017 4KA72X645T01 First edition ...
Page 425: ......