4-53
Group 22 PM Motor Parameters
Code
Parameters
Setting Range
Default Unit
Control Mode
Attribute
V/F SLV
PM
SLV
22-00 PM Motor Rated Power 0.00~600.00
KVA
kW
X
X
O
22-02 PM Motor Rated Current 25%~200% inverter rated current
KVA
A
X
X
O
22-03 PM Motor
‘
s Pole Number 2~96
8
Poles
X
X
O
22-04
PM Motor
’
s
Rotation Speed
0~60000
1500
RPM
X
X
O
22-05
PM Motor
’
s Maximum
Rotation Speed
0~60000
1500
RPM
X
X
O
22-06
PM Motor Rated
Frequency
4.8~599.0
75.0
Hz
X
X
O
22-10 PM SLV Start Current
20% ~ 200% Motor Rated Current
50
%
X
X
O
22-11
I/F Mode Start Frequency
Switching Point
1.0 ~ 20.0
10.0
%
X
X
O
22-14
Armature Resistance of
PM Motor
0.001 ~ 30.000
1.000
Ω
X
X
O
22-15
D-axis Inductance of PM
Motor
0.01 ~300.00
10.00
mH
X
X
O
22-16
Q-axis Inductance of PM
Motor
0.01 ~ 300.00
10.00
mH
X
X
O
22-18 Flux-Weakening Limit
0~100
0
%
X
X
O
22-21 PM Motor Tuning
0:PM Motor Tuning is not Active.
1:Parameter Auto-tune
0
-
X
X
O
22-22
Fault History of PM Motor
Tuning
0:None
5:Loop Adjustment is Time Out
7:Other Errors of Motor Tuning
9:Current Abnormity Occurs when
Loop Adjustment
0
-
X
X
O
*4
22-23 PMSLV acceleration time 0.1~10.0
1.0
Sec
X
X
O
22-25
Initial Position Detection
of PM Motor
0:Disable
1:Detected when inverter is running
1
-
X
X
O
Summary of Contents for E510-201-SH
Page 1: ......
Page 28: ...3 14 b 200V 2HP 1 3PH 200V 3HP 20HP 400V 3HP 25HP IP20 NEMA1 ...
Page 29: ...3 15 c 200V 25HP 400V 30HP d 200V 30HP 40HP 400V 40HP 75HP ...
Page 51: ...3 37 3 5 Standard Wiring 10V AI1 AI2 AGND E P P ...
Page 72: ...4 6 4 1 4 Example of keypad operation Example 1 Modifying parameters ...
Page 74: ...4 8 4 1 5 Operation control ...
Page 206: ...4 140 Acceleration Deceleration calculation of mode 2 ...
Page 316: ...4 250 6 Timer mode 6 FLASH Timer mode 2 7 Timer mode 7 FLASH Timer mode 3 ...
Page 424: ...REVISIONS Date Manual Number Revision May 2017 4KA72X645T01 First edition ...
Page 425: ......