4-96
01- 02
Base frequency of motor 1
Range
【4.8~599.0】Hz
01- 03
Maximum output voltage of motor 1
Range
200V:【0.1~255.0】V
400V:【0.2~510.0】V
01- 04
Middle output frequency 2 of motor 1
Range
【0.0~599.0】Hz
01- 05
Middle output voltage 2 of motor 1
Range
200V:【0.0~255.0】V
400V:【0.0~510.0】V
01- 06
Middle output frequency 1 of motor 1
Range
【0.0~599.0】Hz
01- 07
Middle output voltage 1 of motor 1
Range
200V:【0.0~255.0】V
400V:【0.0~510.0】V
01- 08
Minimum output frequency of motor 1
Range
【0.0~599.0】Hz
01- 09
Minimum output voltage of the motor 1
Range
200V:【0.0~255.0】V
400V:【0.0~510.0】V
01- 12
Base frequency of motor 1
Range
【4.8~599.0】Hz
01- 13
Base output voltage of motor 1
Range
200V:【0.0~255.0】V
400V:【0.0~510.0】V
V/F curve setting (01-02~01-09 and 01-12~01-13)
Select any of the predefined V/F curves setting 0 to E that best matches your application and
the load characteristic of your motor, choose a custom curve setting F or FF to set a custom
curve.
When setting the frequency related parameters for a custom V/F curve values make sure as
follows, the SE03 V/F curve tuning error is displayed when the frequency values are set
incorrectly.
F
max
> F
base
> F
mid2
> F
mid1
>F
min
(01-02) (01-12) (01-04) (01-06) (01-08)
When 01-04 and 01-05 (or 01-18 and 01-19) are set to 0, the inverter ignores the set
values of Fmin2 and Vmin2
The voltage values for 01-02~01-09 are irrelevant.
The value for maximum output voltage of motor 1(01-03) and the value for base output voltage
of motor 1(01-13) will depend on restore factory setting(13-08) to set the value of voltage.
When the control mode is changed parameter 00-00, 01-08 (F
min
) and 01-09 (V
min
) will
automatically be changed to the default setting of the selected control mode.
Custom V/F Curve Setting.
Summary of Contents for E510-201-SH
Page 1: ......
Page 28: ...3 14 b 200V 2HP 1 3PH 200V 3HP 20HP 400V 3HP 25HP IP20 NEMA1 ...
Page 29: ...3 15 c 200V 25HP 400V 30HP d 200V 30HP 40HP 400V 40HP 75HP ...
Page 51: ...3 37 3 5 Standard Wiring 10V AI1 AI2 AGND E P P ...
Page 72: ...4 6 4 1 4 Example of keypad operation Example 1 Modifying parameters ...
Page 74: ...4 8 4 1 5 Operation control ...
Page 206: ...4 140 Acceleration Deceleration calculation of mode 2 ...
Page 316: ...4 250 6 Timer mode 6 FLASH Timer mode 2 7 Timer mode 7 FLASH Timer mode 3 ...
Page 424: ...REVISIONS Date Manual Number Revision May 2017 4KA72X645T01 First edition ...
Page 425: ......