4-102
Motor core loss (02-13)
Set motor core loss as the percentage of the motor rated power
Note:In V/F mode motor core loss (o2-13) is used to for torque compensation.
02-15
Resistance between wires of motor 1
Range
1~60.000
02-16
Rotor resistance gain
Range
1~60.000
02-17
Resistance between wires of motor <1>
Range
1~60.000
02- 19
No-Load Voltage of motor 1
Range
【0.01~600.00】A
02- 20
No-Load Current of motor 2
Range
【0.01~600.00】A
02- 21
Rated current of motor 2
Range
10%~200% of inverter rated current
02-22
Rated rotation speed of motor 2
Range
【0~60000】rpm
02- 23
Rated voltage of motor 2
Range
200V:【50.0~240.0】V
400V:【100.0~480.0】V
02- 24
Rated power of motor 2
Range
【0.01~600.00】KW
02-25
Rated frequency of motor 2
Range
【4.8~599.0】Hz
02-26
Pole of motor 2
Range
【2~16】
02-32
Resistance between wires of motor 2
Range
【0.001~60.000】Ω
02-33
Proportion of Motor Leakage Inductance
<1>
Range
【0.1~15.0】%
Im : 02-09 Excitation Current
Ks1: 02-10 Motor Core Saturation Coefficients 1
Ks2: 02-11 Motor Core Saturation Coefficients 2
Ks3: 02-12 Motor Core Saturation Coefficients 3
Summary of Contents for E510-201-SH
Page 1: ......
Page 28: ...3 14 b 200V 2HP 1 3PH 200V 3HP 20HP 400V 3HP 25HP IP20 NEMA1 ...
Page 29: ...3 15 c 200V 25HP 400V 30HP d 200V 30HP 40HP 400V 40HP 75HP ...
Page 51: ...3 37 3 5 Standard Wiring 10V AI1 AI2 AGND E P P ...
Page 72: ...4 6 4 1 4 Example of keypad operation Example 1 Modifying parameters ...
Page 74: ...4 8 4 1 5 Operation control ...
Page 206: ...4 140 Acceleration Deceleration calculation of mode 2 ...
Page 316: ...4 250 6 Timer mode 6 FLASH Timer mode 2 7 Timer mode 7 FLASH Timer mode 3 ...
Page 424: ...REVISIONS Date Manual Number Revision May 2017 4KA72X645T01 First edition ...
Page 425: ......