4
-
138
05- 38
Preser Speed 10-Dec time
05- 39
Preser Speed 11-Acc time
05- 40
Preser Speed 11-Dec time
05- 41
Preser Speed 12-Acc time
05- 42
Preser Speed 12-Dec time
05- 43
Preser Speed 13-Acc time
05- 44
Preser Speed 13-Dec time
05- 45
Preser Speed 14-Acc time
05- 46
Preser Speed 14-Dec time
05- 47
Preser Speed 15-Acc time
05- 48
Preser Speed 15-Dec time
Range
【
0.0~6000.0
】 Sec
When 05-00=0, accel/decal set by parameter 00-14~00-17/00-21~00-24.
When 05-00=1, individual accel/decal apply to each preset speed 0~15, parameters
05-17~05-48.
Formula for calculating acceleration and deceleration time:
When 01-00=F, maximum output frequency set by 01-02.
When 01-00≠F, maximum output frequency is 50.00 (or 60.00/90.00/120.0/180.0)
Example:
01-00≠F, 01-02=50Hz (maximum output frequency), 05-02=10Hz (presser speed 1),
05-17=5s (Accel-time), 05-18=20s (Decel-time)
Example:
Acceleration/Deceleration timing when 05-00=1 is set to 1.
In this example the following parameters are set:
00-02=1 (External terminal operation)
S1:03- 00=0 (Terminal S1:Forward/stop)
S2:03- 01=1 (Terminal S2:Reverse/stop)
S3:03- 02=2 (Terminal S3:Preset speed 1)
S4:03- 03=3 (Terminal S4:Preset speed 2)
S5:03- 03=4 (Terminal S5:Preset speed 3)
Summary of Contents for E510-201-SH
Page 1: ......
Page 28: ...3 14 b 200V 2HP 1 3PH 200V 3HP 20HP 400V 3HP 25HP IP20 NEMA1 ...
Page 29: ...3 15 c 200V 25HP 400V 30HP d 200V 30HP 40HP 400V 40HP 75HP ...
Page 51: ...3 37 3 5 Standard Wiring 10V AI1 AI2 AGND E P P ...
Page 72: ...4 6 4 1 4 Example of keypad operation Example 1 Modifying parameters ...
Page 74: ...4 8 4 1 5 Operation control ...
Page 206: ...4 140 Acceleration Deceleration calculation of mode 2 ...
Page 316: ...4 250 6 Timer mode 6 FLASH Timer mode 2 7 Timer mode 7 FLASH Timer mode 3 ...
Page 424: ...REVISIONS Date Manual Number Revision May 2017 4KA72X645T01 First edition ...
Page 425: ......