Group 06 Automatic Program Operation
06- 00
Auto Run Mode Select
Range
【0】:
Disable
【1】:
Execute a single cycle operation. Restart speed is based on the previous
stopped speed.
【2】:
Execute continuous cycle operation. Restart speed is based on the
previous cycle stop speed.
【3】:
After completion of a single cycle, the on-going operation speed is
based on the speed of the last stage. Restart speed is based on the
previous stopped speed.
【4】:
Execute a single cycle operation. Restart speed is based on the
Speed-Stage 0.
【5】:
Execute continuous cycle operation. Restart speed is based on the
Speed-Stage 0.
【6】:
After completion of a single cycle, the on-going operation speed is
based on the speed of the last stage. Restart speed is based on the
Speed-Stage 0
Range
【0.00~599.00】Hz
Frequency setting of speed-stage 0 is based on parameter 05-01
06- 01
Frequency setting of speed-stage 1
06- 02
Frequency setting of speed-stage 2
06- 03
Frequency setting of speed-stage 3
06- 04
Frequency setting of speed-stage 4
06- 05
Frequency setting of speed-stage 5
06- 06
Frequency setting of speed-stage 6
06- 07
Frequency setting of speed-stage 7
06- 08
Frequency setting of speed-stage 8
06- 09
Frequency setting of speed-stage 9
06- 10
Frequency setting of speed-stage 10
06- 11
Frequency setting of speed-stage 11
06- 12
Frequency setting of speed-stage 12
06- 13
Frequency setting of speed-stage 13
06- 14
Frequency setting of speed-stage 14
06- 15
Frequency setting of speed-stage 15
Summary of Contents for E510-201-SH
Page 1: ......
Page 28: ...3 14 b 200V 2HP 1 3PH 200V 3HP 20HP 400V 3HP 25HP IP20 NEMA1 ...
Page 29: ...3 15 c 200V 25HP 400V 30HP d 200V 30HP 40HP 400V 40HP 75HP ...
Page 51: ...3 37 3 5 Standard Wiring 10V AI1 AI2 AGND E P P ...
Page 72: ...4 6 4 1 4 Example of keypad operation Example 1 Modifying parameters ...
Page 74: ...4 8 4 1 5 Operation control ...
Page 206: ...4 140 Acceleration Deceleration calculation of mode 2 ...
Page 316: ...4 250 6 Timer mode 6 FLASH Timer mode 2 7 Timer mode 7 FLASH Timer mode 3 ...
Page 424: ...REVISIONS Date Manual Number Revision May 2017 4KA72X645T01 First edition ...
Page 425: ......