4
-
142
Range
【0.0~6000.0】Sec
06- 16
Operation time setting of speed-stage 0
06- 17
Operation time setting of speed-stage 1
06- 18
Operation time setting of speed-stage 2
06- 19
Operation time setting of speed-stage 3
06- 20
Operation time setting of speed-stage 4
06- 21
Operation time setting of speed-stage 5
06- 22
Operation time setting of speed-stage 6
06- 23
Operation time setting of speed-stage 7
06- 24
Operation time setting of speed-stage 8
06- 25
Operation time setting of speed-stage 9
06- 26
Operation time setting of speed-stage 10
06- 27
Operation time setting of speed-stage 11
06- 28
Operation time setting of speed-stage 12
06- 29
Operation time setting of speed-stage 13
06- 30
Operation time setting of speed-stage 14
06- 31
Operation time setting of speed-stage 15
Range
【0】:Stop
【1】:Forward
【2】:Reverse
06- 32
Operation direction selection of speed-stage 0
06- 33
Operation direction selection of speed-stage 1
06- 34
Operation direction selection of speed-stage 2
06- 35
Operation direction selection of speed-stage 3
06- 36
Operation direction selection of speed-stage 4
06- 37
Operation direction selection of speed-stage 5
06- 38
Operation direction selection of speed-stage 6
06- 39
Operation direction selection of speed-stage 7
06- 40
Operation direction selection of speed-stage 8
06- 41
Operation direction selection of speed-stage 9
06- 42
Operation direction selection of speed-stage 10
06- 43
Operation direction selection of speed-stage 11
06- 44
Operation direction selection of speed-stage 12
06- 45
Operation direction selection of speed-stage 13
06- 46
Operation direction selection of speed-stage 14
06- 47
Operation direction selection of speed-stage 15
Auto run mode uses frequency reference parameters (05-01, 06-01~06-15), operation time
parameters (06-16~06-31) and direction of operation parameter (06-32~06-47)
Auto run mode can not be used when
“
Wobble Frequency function
”
or
“
PID function
”
is
enabled.
In auto run mode, multi-speed frequency reference of external signal 1~4 (03-00~03-07=2~5)
is disabled.
Summary of Contents for E510-201-SH
Page 1: ......
Page 28: ...3 14 b 200V 2HP 1 3PH 200V 3HP 20HP 400V 3HP 25HP IP20 NEMA1 ...
Page 29: ...3 15 c 200V 25HP 400V 30HP d 200V 30HP 40HP 400V 40HP 75HP ...
Page 51: ...3 37 3 5 Standard Wiring 10V AI1 AI2 AGND E P P ...
Page 72: ...4 6 4 1 4 Example of keypad operation Example 1 Modifying parameters ...
Page 74: ...4 8 4 1 5 Operation control ...
Page 206: ...4 140 Acceleration Deceleration calculation of mode 2 ...
Page 316: ...4 250 6 Timer mode 6 FLASH Timer mode 2 7 Timer mode 7 FLASH Timer mode 3 ...
Page 424: ...REVISIONS Date Manual Number Revision May 2017 4KA72X645T01 First edition ...
Page 425: ......