4
-
181
While sleep mode is active and the motor has stopped, the internal PID control is still in operating.
When the reference frequency increases and exceeds the wakeup frequency parameter 10-19 for
the time specified in the wakeup delay time parameter 10-20, the inverter will restart and the output
frequency will ramp up to the reference frequency.
Example:
(1)
When wakeup frequency less than sleep frequency, inverter starts by the sleep frequency and
sleeps depending on sleep frequency.
(2)
When wakeup frequency greater than sleep frequency, inverter starts by the wakeup frequency
and sleeps depending on sleep frequency.
Parameter 10-00 and 10-01 can not be set to the same source. If both parameters are set to the
same source the keypad will show a
“
SE05
”
alarm.
When 10-29=1 or 2 and then 10-25=1, inverter will show a
“
SE05
”
alarm.
When 10-29=1 or 2, and then set 10-03=1xxxb, inverter will show a
“
SE05
”
alarm.
When 10-29= 0:PID sleep function is disabled.
When 10-29= 1:PID sleep operation is based on parameter 10-17 and 10-18.
When 10-29= 2:PID sleep function is started by multi-function digital input terminal.
10-27
PID Feedback Display Bias
Range
【
0~9999
】
PID feedback value bias can be monitored by parameter 10-27 (PID feedback bias display).
Example:The feedback signal of 0-10V / 4-20mA is a pressure transducer.
Refer to the figure 4.3.84 for displaying the unit conversion.
Figure 4.3.84 Feedback signal scaling
Example:
Feedbacl signal:0V=0%=1.0 PSI,10V=100%=20.0 PSI
Parameter setting:10-27=10 (0% feedback value)
10-33=200 (100% feedback value)
Summary of Contents for E510-201-SH
Page 1: ......
Page 28: ...3 14 b 200V 2HP 1 3PH 200V 3HP 20HP 400V 3HP 25HP IP20 NEMA1 ...
Page 29: ...3 15 c 200V 25HP 400V 30HP d 200V 30HP 40HP 400V 40HP 75HP ...
Page 51: ...3 37 3 5 Standard Wiring 10V AI1 AI2 AGND E P P ...
Page 72: ...4 6 4 1 4 Example of keypad operation Example 1 Modifying parameters ...
Page 74: ...4 8 4 1 5 Operation control ...
Page 206: ...4 140 Acceleration Deceleration calculation of mode 2 ...
Page 316: ...4 250 6 Timer mode 6 FLASH Timer mode 2 7 Timer mode 7 FLASH Timer mode 3 ...
Page 424: ...REVISIONS Date Manual Number Revision May 2017 4KA72X645T01 First edition ...
Page 425: ......