4-211
Rotational auto-tuning (17-00=0)
Inverter can provide higher quality for motors. After executing Rotational auto-tuning (17-00),
Excitation current of motor 1 (02-09)、Core saturation coefficient 1 of motor 1(02-10)、Core
saturation coefficient 2 of motor 1 and Core saturation coefficient 3 of motor 1 (02-12) will renew
the value.
Static auto-tuning (17-00=1)
Static auto-tuning won
’
t rotate the motor while auto-tuning. After executing Static auto-tuning
(17-00=1), Proportion of motor leakage inductance (02-33) and Motor slip (02-34) will renew the
value.
Stator resistance measurement (17-00=2)
Stator resistance measurement provides for long motor length (exceed 50 meters). After executing
Stator resistance measurement (17-00=2), Resistance between wires of motor 1(02-15) will renew
the value.
Loop tuning (17-00=4)
Loop tuning (17-00=4) provide great response of current circuit, it can improve frequency
bandwidth of current and torque.
Rotation Auto-tuning Combination (17-00=5)
Rotation Auto-tuning Combination is the auto-tuning for three in one, including Loop tuning
(17-00=4), Stator resistance measurement (17-00=2) and Rotational auto-tuning (17-00=0).
Static Auto-tune Combination (17-00=6)
Static Auto-tune Combination (17-00=6) is the auto-tuning for three in one, including Loop tuning
(17-00=4)、Stator resistance measurement (17-00=2) and Static auto-tuning (17-00=1)
Motor rated output power (17-01)
Set by inverter capacity (13-00) according to the nameplate of motor.
Motor rated current (17-02)
(1)
Set by inverter capacity (13-00) according to the nameplate of motor.
(2)
In V/F mode, set the range to 10~120 % of the inverter rated current.
(3)
In SLV mode, set the range to 25~120% of the inverter rated current.
Motor rated voltage (17-03)
Prevent the inverter output voltage from saturation when the motor rated voltage is higher than the
inverter input voltage (see Example 1).
Motor rated frequency (17-04)
Please set the value according to motor nameplate
Motor rated speed (17-05)
Please set the value according to motor nameplate
Summary of Contents for E510-201-SH
Page 1: ......
Page 28: ...3 14 b 200V 2HP 1 3PH 200V 3HP 20HP 400V 3HP 25HP IP20 NEMA1 ...
Page 29: ...3 15 c 200V 25HP 400V 30HP d 200V 30HP 40HP 400V 40HP 75HP ...
Page 51: ...3 37 3 5 Standard Wiring 10V AI1 AI2 AGND E P P ...
Page 72: ...4 6 4 1 4 Example of keypad operation Example 1 Modifying parameters ...
Page 74: ...4 8 4 1 5 Operation control ...
Page 206: ...4 140 Acceleration Deceleration calculation of mode 2 ...
Page 316: ...4 250 6 Timer mode 6 FLASH Timer mode 2 7 Timer mode 7 FLASH Timer mode 3 ...
Page 424: ...REVISIONS Date Manual Number Revision May 2017 4KA72X645T01 First edition ...
Page 425: ......