4-227
PM Motor Tuning (22-21)
WARNING!
The inverter and motor may start unexpectedly during Auto-Tuning, which could result in death or
serious injury. Make sure the area surrounding of the motor and load are clear before proceeding
with Auto-Tuning.
(1)
Please set 00-00=5 and then set 22-21=1, before selecting PM motor tuning, enter the motor
data (22-00)~(22-06) according to the motor nameplate and the number of encoder pulses
(20-27).
(2)
When 22-21=1, press the enter key to go to the PM motor tuning screen. The keypad will
display the message of
“
IPrdy
”
(Ready to Tune), press run to start the PM motor tuning. The
keypad will display the
“
IPtun
”
message during auto-tune.
(3)
If the motor is successfully tuned, the message of
“
IPEnd
”
will be displayed. If auto-tune is
aborted with the stop key, the operator will display the message of
“
IPbrd
“
(PM motor tuning
aborted).
Note:
If inverter already performed motor auto tuning, it is not required to perform motor tuning
again when re-powered up.
PM SLV acceleration time (22-23)
PM SLV acceleration time is the acceleration time from static to I/F Mode Start Frequency Switching
Point (22-11).
Note:
If occur error or vibration in PMSLV mode. Suggest to increase or decrease acceleration time. Please
adjust acceleration time by different application.
Initial position detection of PM motor (22-25)
Use for PMSLV control mode.
When 22-25=1, inverter will detect the initial position of motor rotator while motor is starting to run.
It can prevent the motor reverse the stator.
When 22-25=0, detection function is disabled, inverter will not perform the detection while motor is
running. If the motor does not allow to run, please use this mode.
Summary of Contents for E510-201-SH
Page 1: ......
Page 28: ...3 14 b 200V 2HP 1 3PH 200V 3HP 20HP 400V 3HP 25HP IP20 NEMA1 ...
Page 29: ...3 15 c 200V 25HP 400V 30HP d 200V 30HP 40HP 400V 40HP 75HP ...
Page 51: ...3 37 3 5 Standard Wiring 10V AI1 AI2 AGND E P P ...
Page 72: ...4 6 4 1 4 Example of keypad operation Example 1 Modifying parameters ...
Page 74: ...4 8 4 1 5 Operation control ...
Page 206: ...4 140 Acceleration Deceleration calculation of mode 2 ...
Page 316: ...4 250 6 Timer mode 6 FLASH Timer mode 2 7 Timer mode 7 FLASH Timer mode 3 ...
Page 424: ...REVISIONS Date Manual Number Revision May 2017 4KA72X645T01 First edition ...
Page 425: ......