4- 242
4.4
Built-in PLC function
The PLC ladder logic can be created and downloaded by TECO DriveLink software.
4.4.1 Basic Command
P
NO / NC
Inputs
I
i
I1
I8 / i1
i8
Outputs
Q
Q
Q
Q
Q
q
Q1
Q2 / q1
q2
Auxiliary command
M
M
M
M
M
m
M1
MF / m1
mF
Special registers
V1~V7
Counter function
C
C
c
C1~C8 / c1~c8
Timer function
T
T
t
T1
T8 / t1
t8
Analog comparison
function
G
G
g
G1
G8 / g1
g8
Operation control function
F
F
f
F1~F8 / f1~f8
summation and
subtraction function
AS
AS1~4
Multiplication and division
function
MD
MD1~4
Description of special registers
V1:Set frequency
Range:0.1~599.0Hz
V2:Operation frequency
Range:0.1~599.0Hz
V3:AI1 input value
Range:0~1000
V4:AI2 input value
Range:0~1000
V5:Keypad input value
Range:0~1000
V6:Operation current
Range:0.1~999.9A
V7:Torque value
Range:0.1~200.0%
Command
Upper Differential Lower Differential Other command symbol
Differential command
D
d
SET command
RESET command
P command
P
Open circuit
“ “
Short circuit
“--”
Connection symbol
Definition
─
Connect components on the left and right side
┴
Connects components on the left , right and top side
┼
Connects components on the left , right , top and bottom side
┬
Connects components on the left , right and bottom side
Summary of Contents for E510-201-SH
Page 1: ......
Page 28: ...3 14 b 200V 2HP 1 3PH 200V 3HP 20HP 400V 3HP 25HP IP20 NEMA1 ...
Page 29: ...3 15 c 200V 25HP 400V 30HP d 200V 30HP 40HP 400V 40HP 75HP ...
Page 51: ...3 37 3 5 Standard Wiring 10V AI1 AI2 AGND E P P ...
Page 72: ...4 6 4 1 4 Example of keypad operation Example 1 Modifying parameters ...
Page 74: ...4 8 4 1 5 Operation control ...
Page 206: ...4 140 Acceleration Deceleration calculation of mode 2 ...
Page 316: ...4 250 6 Timer mode 6 FLASH Timer mode 2 7 Timer mode 7 FLASH Timer mode 3 ...
Page 424: ...REVISIONS Date Manual Number Revision May 2017 4KA72X645T01 First edition ...
Page 425: ......