5-13
Warning Message (LCD display only)
LCD display
Description
Cause
Possible solutions
Operator Copy
Error
Parameters can not
upload to operator
Inverter data transmission
error, can not upload the
data to operator
Check operator and
control connection
RDE
Operator Write
Error
Operator can not write
data to inverter
The control mode in the
operator does not match
the inverter.
The model name in the
operator does not match
the inverter.
The firmware version in
the operator does not
match the inverter.
Check the control mode,
model name and
firmware version of
inverter.
WRE
Operator
Compare Error
Data compare incorrect
between operator and
inverter.
When operator upload or
download the data, user can
compare the data of
operator and inverter, when
data of both side does not
match, operator will show
“VRYE” error.
Check operator and
control connection
VRYE
Does Not Allow
to Read and Save
Data
Operator can not read or
save inverter parameters
When 16-08=0, does not
allow to read inverter
parameters or save them to
the operator.
Check parameter setting
of parameter (16-08)
RDP
Summary of Contents for E510-201-SH
Page 1: ......
Page 28: ...3 14 b 200V 2HP 1 3PH 200V 3HP 20HP 400V 3HP 25HP IP20 NEMA1 ...
Page 29: ...3 15 c 200V 25HP 400V 30HP d 200V 30HP 40HP 400V 40HP 75HP ...
Page 51: ...3 37 3 5 Standard Wiring 10V AI1 AI2 AGND E P P ...
Page 72: ...4 6 4 1 4 Example of keypad operation Example 1 Modifying parameters ...
Page 74: ...4 8 4 1 5 Operation control ...
Page 206: ...4 140 Acceleration Deceleration calculation of mode 2 ...
Page 316: ...4 250 6 Timer mode 6 FLASH Timer mode 2 7 Timer mode 7 FLASH Timer mode 3 ...
Page 424: ...REVISIONS Date Manual Number Revision May 2017 4KA72X645T01 First edition ...
Page 425: ......