5-24
Items
Details
Checking
period
Methods
Criteria
Remedies
Daily 1Year
protrusion
Power
component
Any dust or debris
◎
Clean
components
Check resistance
between each
terminals
◎
Measure with
a multi-tester
No short circuit
or broken
circuit in
three-phase
output
Consult with
the supplier
Peripheral device
Rheostat
Whether rheostat
wiring or connector
are damaged
◎
Visual check
No
abnormalities
Replacement
rheostat
Electromagnetic
Contactor
Check contacts and
connections for any
abnormality.
◎
Replacement
Contactor
Unusual vibration
and noise
◎
hearing check
Reactor
Is there any
abnormalities?
◎
Visual check
Replacement
Reactor
Cooling System
Cooling fan
Unusual vibration
and noise
◎
Visual or
hearing check
Correct
cooling
Consult with
the supplier
Excessive dust or
debris
◎
Visual check
Clean the fan
Heat sink
Excessive dust or
debris
◎
Clean up
debris or dust
Ventilation Path
Is the ventilation
path blocked?
◎
Clear the path
Summary of Contents for E510-201-SH
Page 1: ......
Page 28: ...3 14 b 200V 2HP 1 3PH 200V 3HP 20HP 400V 3HP 25HP IP20 NEMA1 ...
Page 29: ...3 15 c 200V 25HP 400V 30HP d 200V 30HP 40HP 400V 40HP 75HP ...
Page 51: ...3 37 3 5 Standard Wiring 10V AI1 AI2 AGND E P P ...
Page 72: ...4 6 4 1 4 Example of keypad operation Example 1 Modifying parameters ...
Page 74: ...4 8 4 1 5 Operation control ...
Page 206: ...4 140 Acceleration Deceleration calculation of mode 2 ...
Page 316: ...4 250 6 Timer mode 6 FLASH Timer mode 2 7 Timer mode 7 FLASH Timer mode 3 ...
Page 424: ...REVISIONS Date Manual Number Revision May 2017 4KA72X645T01 First edition ...
Page 425: ......