6-6
Model
Braking
Unit
Specifications of Braking Resistor
Dimension of
Braking Resistor
Braking
Torque
Minimum
Resistance
V HP KW
Model Qty
Number of Braking
Resistor
Qty
(W) (Ω )
(LxWxH)
mm
Qty
10%
ED
(Ω )
(W)
20 15
-
-
JNBR-1R5KW40
1 1500 40
1500W/40Ω
(615x60x110)
1
119
22 3000
25 18.5
-
-
JNBR-4R8KW32
1 4800 32
1200W/32Ω
(535x60x110)
4
117
14 4800
30 22
-
-
JNBR-4R8KW27R2
1 4800 27.2
1200W/27.2Ω
(535x60x110)
4
117
14 4800
40 30
-
-
JNBR-6KW20
1 6000 20
1500W/20Ω
(615x60x110)
4
119
11 6000
50 37
TBU-430
2
JNBR-4R8KW32
2 4800 32
1200W/32Ω
(535x60x110)
8
119
19.2 3600
60 45
TBU-430
2
JNBR-4R8KW27R2
2 4800 27.2
1200W/27.2Ω
(535x60x110)
8
117
19.2 3600
75 55
TBU-430
2
JNBR-6KW20
2 6000 20
1500W/20Ω
(615x60x110)
8
126
19.2 3600
Note:
Formula for brake resistor
:W= (Vpnb * Vpnb) * ED% / Rmin
(1)
W:
braking resistor power (Watts)
(2)
Vpnb:
braking voltage (220V=380VDC, 440V=760VDC)
(3)
ED%:
braking effective period
(4)
R
min
:
braking resistor minimum value (ohms)
6.6 Input noise filter
Install a noise filter on power supply side to eliminate noise transmitted between the power
line and the inverter. The inverter noise filter shown in table belowmeets the EN61800-5-1.
Frame
Model
Input Voltage
Number of Filter
(A)
1
2P5/
201
-SH
1Φ /3Φ 200~240V
E2F-2102/FN3258-16-45
10/16
2
202/
203
-SH1(F)
FS6146-27-07/FN3258-16-45
27/16
1
202-SH3
3Φ 200~240V
FN3258-16-45
16
2
205-SH3
FS20500-22-99
22
3
208/210-SH3
T-096.05001.00
50
4
215/220-SH3
T-097.08004.00
80
5
225-SH3
FS32125-86-99
86
6
230/240-SH3
FS32125-150-99
150
1
401/402-SH3(F)
3Φ 380~480V
FN3258-16-45
16
2
403/405-SH3(F)
3
408/410/415-SH3(F)
T-097.08004.00
80
4
420/425-SH3(F)
FS42500-50-99
80
5
430-SH3(F)
JN5-FLT-63A
63
6
440/450/460-SH3(F)
JN5-FLT-112A
112
6
475-SH3(F)
FS32126-181-99
181
Summary of Contents for E510-201-SH
Page 1: ......
Page 28: ...3 14 b 200V 2HP 1 3PH 200V 3HP 20HP 400V 3HP 25HP IP20 NEMA1 ...
Page 29: ...3 15 c 200V 25HP 400V 30HP d 200V 30HP 40HP 400V 40HP 75HP ...
Page 51: ...3 37 3 5 Standard Wiring 10V AI1 AI2 AGND E P P ...
Page 72: ...4 6 4 1 4 Example of keypad operation Example 1 Modifying parameters ...
Page 74: ...4 8 4 1 5 Operation control ...
Page 206: ...4 140 Acceleration Deceleration calculation of mode 2 ...
Page 316: ...4 250 6 Timer mode 6 FLASH Timer mode 2 7 Timer mode 7 FLASH Timer mode 3 ...
Page 424: ...REVISIONS Date Manual Number Revision May 2017 4KA72X645T01 First edition ...
Page 425: ......