3-29
Model: E510-
□ □ □
- SH3(F)
430
440
Horse power (HP)
30
40
HD/ND Suitable motor capacity (kW)
22/30
30/37
HD/ND Rated output current (A)
45/58
60/73
HD/ND Rated capacity (KVA)
34.3/44.2
45.7/55.6
Input voltage range(V)
Three phase : 380~480V,50/60Hz
Allowable voltage fluctuation
+10%-15%
Output voltage range(V)
Three phase : 0~480V
Input current (A)*
48.9/63
65.2/78.3
Inverter net weight (KG)
10
24
Inverter net weight(with Filter) (KG)
22.8
47.2
Allowable momentary power loss time(s)
2.0
Enclosure
IP20/NEMA1
Model: E510-
□ □ □
- SH3(F)
450
460
475
Horse power (HP)
50
60
75
HD/ND Suitable motor capacity (kW)
37/45
45/55
55/75
HD/ND Rated output current (A)
75/88
91/103
118/145
HD/ND Rated capacity (KVA)
57.2/67.1
69.3/78.5
89.9/111
Input voltage range(V)
Three phase : 380~480V,50/60Hz
Allowable voltage fluctuation
+10%-15%
Output voltage range(V)
Three phase : 0~480V
Input current (A)*
81.5/95.7
98.9/112
130/159
Inverter net weight (KG)
24
24
24
Inverter net weight(with Filter) (KG)
47.2
47.2
52.2
Allowable momentary power loss time(s)
2.0
2.0
2.0
Enclosure
IP20/NEMA1
Notes:
1.
Take standard 4-poles induction motor as the base.
2.
E510s model is designed to use inheavy duty conritions, the factory setting is HD (Heavy Duty
type) mode.
3.
The overload capacity of E510s model HD (Heavy Duty) is 150%/1min, 200%/2sac. See the table
below for the carrier frequency default setting and range.
4.
The overload capacity of E510s model ND (Normal Duty) is 120%/1min, carrier frequency range is
1kHz~16kHz, the default setting is 2kHz.
5.
If the carrier frequency is greater than default, it need to adjust the load current based on the
de-rating curve.
Inverter voltage and capacity
HD mode carrier frequency range
ND mode carrier
frequency range
200V Class
400V Class
V/F
SLV
PMSLV
1~20HP
1~25HP
1~16kHz
4~16kHz
4~8kHz
5kHz
30HP
1~16kHz
4~16kHz(6)
4~8kHz
5kHz
25~40HP
40~50HP
1~12kHz
4~12kHz(6)
4~8kHz
5kHz
60~75HP
1~10kHz
4~10kHz
4~8kHz
5kHz
Summary of Contents for E510-201-SH
Page 1: ......
Page 28: ...3 14 b 200V 2HP 1 3PH 200V 3HP 20HP 400V 3HP 25HP IP20 NEMA1 ...
Page 29: ...3 15 c 200V 25HP 400V 30HP d 200V 30HP 40HP 400V 40HP 75HP ...
Page 51: ...3 37 3 5 Standard Wiring 10V AI1 AI2 AGND E P P ...
Page 72: ...4 6 4 1 4 Example of keypad operation Example 1 Modifying parameters ...
Page 74: ...4 8 4 1 5 Operation control ...
Page 206: ...4 140 Acceleration Deceleration calculation of mode 2 ...
Page 316: ...4 250 6 Timer mode 6 FLASH Timer mode 2 7 Timer mode 7 FLASH Timer mode 3 ...
Page 424: ...REVISIONS Date Manual Number Revision May 2017 4KA72X645T01 First edition ...
Page 425: ......