4-23
Group 03 External Digital Input and Output Parameters
Code
Parameter Name
Setting Range
Default Unit
Control mode
Attribute
V/F SLV
PM
SLV
37:Detection Output of PID Feedback Loss
54:Turn on short-circuit braking
55:Low Current Detection
59:OH Detection
O
O
O
X
X
O
03-12
Relay (R2A-R2B)
Output
0
-
O
O
O
O
O
O
03-13
Frequency Detection
Level
0.0~599.0
0.0
Hz
O
O
O
03-14
Frequency Detection
Width
0.1~25.5
2.0
Hz
O
O
O
03-15 Current Agree Level 0.1~999.9
0.1
A
O
O
O
03-16
Delay Time of Current
Agree Detection
0.1~10.0
0.1
s
O
O
O
03-17
* Mechanical Braking
Release Level
0.00~20.00
0.00
Hz
O
O
O
03-18
* Mechanical Braking
Level Set
0.00~20.00
0.00
Hz
O
O
O
03-19 Relay (R1A-R2B) Type
xxx0b:R1 A Contact, xxx1b:R1 B Contact
0000b
-
O
O
O
xx0xb:R2 A Contact, xx1xb:R2 B Contact
03-20
Internal / External
Multi-Function Input
Terminal Selection
0~63
0
O
O
O
03-21
Action To Set The
Internal
Multi-Function Input
Terminals
0~
63
0
O
O
O
03-22 Pre-Set Count 1
0~9999
0
O
O
O
03-23 Pre-Set Count 2
0~9999
0
O
O
O
03-24
Output Under Current
Detection
0:Invalid
0
O
O
O
1:Valid
03-25
Output Under Current
Detection Level
0~999.9
0.1
A
O
O
O
03-26
Output Under Current
Detection Delay Time
0.0~655.3
4
s
0.01
s
O
O
O
03-27 Pulse Frequency
50~25000
200
Hz
O
O
O
*1
03-28 Pulse Input Gain
0.0~1000.0
100.0
%
O
O
O
*1
03-30
Selection of Pulse
Input
0:General Pulse Input
0
-
O
O
O
1:PWM
03-33 Pulse Input Bias
-100.0~100.0
0.0
%
O
O
O
*1
03-34
Filter Time of Pulse
Input
0.00~2.00
0.1
s
O
O
O
*1
03-53 Current Agree Level 2 0.0~999.9
0.1
A
O
O
O
*:If the maximum output frequency of motor is over 300HZ, the frequency resolution is changed to 0.1Hz
Summary of Contents for E510-201-SH
Page 1: ......
Page 28: ...3 14 b 200V 2HP 1 3PH 200V 3HP 20HP 400V 3HP 25HP IP20 NEMA1 ...
Page 29: ...3 15 c 200V 25HP 400V 30HP d 200V 30HP 40HP 400V 40HP 75HP ...
Page 51: ...3 37 3 5 Standard Wiring 10V AI1 AI2 AGND E P P ...
Page 72: ...4 6 4 1 4 Example of keypad operation Example 1 Modifying parameters ...
Page 74: ...4 8 4 1 5 Operation control ...
Page 206: ...4 140 Acceleration Deceleration calculation of mode 2 ...
Page 316: ...4 250 6 Timer mode 6 FLASH Timer mode 2 7 Timer mode 7 FLASH Timer mode 3 ...
Page 424: ...REVISIONS Date Manual Number Revision May 2017 4KA72X645T01 First edition ...
Page 425: ......