4-27
Group
06 Automatic Program Opera
Code
Parameter Name
Setting Range
Default Unit
Control mode
Attribute
V/F
SLV
PM
SLV
06-00 Auto Run Mode Selection
0:Disabled
1:Execute a single cycle operation
mode. Restart speed is based on the
previous stopped speed.
2:Execute continuous cycle operation
mode. Restart speed is based on the
previous stopped speed.
3:After the completion of a single
cycle, the on-going operation speed
is based on the speed of the last
stage. Restart speed is based on the
previous stopped speed.
4:Execute a single cycle operation
mode. Restart speed will be based
on the speed of stage 0.
5:Execute continuous cycle operation
mode. Restart speed will be based
on the speed of stage 0.
6:After the completion of a single
cycle, the on-going operation speed
is based on the speed of the last
stage. Restart speed is based on the
speed of stage 0.
0
-
O
O
X
06-01
* Frequency Setting of
Operation-Stage 1
0.00~599.00
0.0
Hz
O
O
X
*1
06-02
* Frequency Setting of
Operation-Stage 2
0.00~599.00
0.0
Hz
O
O
X
*1
06-03
* Frequency Setting of
Operation-Stage 3
0.00~599.00
0.0
Hz
O
O
X
*1
06-04
* Frequency Setting of
Operation-Stage 4
0.00~599.00
0.0
Hz
O
O
X
*1
06-05
* Frequency Setting of
Operation-Stage 5
0.00~599.00
0.0
Hz
O
O
X
*1
06-06
* Frequency Setting of
Operation-Stage 6
0.00~599.00
0.0
Hz
O
O
X
*1
06-07
* Frequency Setting of
Operation-Stage 7
0.00~599.00
0.0
Hz
O
O
X
*1
06-08
* Frequency Setting of
Operation-Stage 8
0.00~599.00
0.0
Hz
O
O
X
*1
06-09
* Frequency Setting of
Operation-Stage 9
0.00~599.00
0.0
Hz
O
O
X
*1
06-10
* Frequency Setting of
Operation-Stage 10
0.00~599.00
0.0
Hz
O
O
X
*1
Summary of Contents for E510-201-SH
Page 1: ......
Page 28: ...3 14 b 200V 2HP 1 3PH 200V 3HP 20HP 400V 3HP 25HP IP20 NEMA1 ...
Page 29: ...3 15 c 200V 25HP 400V 30HP d 200V 30HP 40HP 400V 40HP 75HP ...
Page 51: ...3 37 3 5 Standard Wiring 10V AI1 AI2 AGND E P P ...
Page 72: ...4 6 4 1 4 Example of keypad operation Example 1 Modifying parameters ...
Page 74: ...4 8 4 1 5 Operation control ...
Page 206: ...4 140 Acceleration Deceleration calculation of mode 2 ...
Page 316: ...4 250 6 Timer mode 6 FLASH Timer mode 2 7 Timer mode 7 FLASH Timer mode 3 ...
Page 424: ...REVISIONS Date Manual Number Revision May 2017 4KA72X645T01 First edition ...