4-32
Group 08 Protection Parameters
Code
Parameter Name
Setting Range
Default Unit
Control mode
Attribute
V/F
SLV
PM
SLV
08-00
Stall Prevention
Function
xxx0b:Stall prevention is enabled in acceleration.
xxx1b:Stall prevention is disabled in acceleration.
xx0xb:Stall prevention is enabled in deceleration.
xx1xb:Stall prevention is disabled in deceleration.
x0xxb:Stall prevention is enabled in operation
x1xxb:Stall prevention is disabled in operation
0xxxb:Stall prevention in operation is based on
deceleration time of speed-stage 1.
1xxxb:Stall prevention in operation is based on
deceleration time of speed-stage 2.
0000b
-
O
O
O
08-01
Stall Prevention Level
During Acceleration
20~200
HD:150
ND:120
%
O
O
O
08-02
Stall Prevention Level
During Deceleration
200V:330V~410V
385V
V
O
O
O
400V:660V~820V
770V
08-03
Stall Prevention Level
During Run
30~200
HD:160
%
O
X
X
ND:120
08-05
Selection for Motor
Overload Protection
(OL1)
xxx0b:Overload Protection is disabled.
xxx1b:Overload Protection is enabled.
xx0xb:Cold Start of Motor Overload
xx1xb:Hot Start of Motor Overload
x0xxb:Standard Motor
x1xxb:Inverter Duty Motor
0xxxb:Reserved
1xxxb:Reserved
0001b
-
O
O
O
08-06
Start-up Mode of
Overload Protection
Operation (OL1)
0:Stop Output after Overload Protection
1:Continuous Operation after Overload
Protection.
0
-
O
O
O
08-07
Cooling Fan Control
0:Start in High Temperature
1:Start in Operation
2:Always Run
3:Stop Operation
1
-
O
O
O
08-08
Auto Voltage
Regulation (AVR)
0:Enable
1:Disable
0
-
O
O
O
08-09
Selection of Input Phase
Loss Protection
0:Disable
1:Enable
0
-
O
O
O
08-10
Selection of Output
Phase Loss Protection
0:Disable
1:Enable
0
-
O
O
O
08-13
Selection of
Over-Torque Detection
0:Over-Torque Detection is Disabled.
1:Start to Detect when Reaching the Set
Frequency.
2:Start to Detect when the Operation is Begun.
0
-
O
O
O
Summary of Contents for E510-201-SH
Page 1: ......
Page 28: ...3 14 b 200V 2HP 1 3PH 200V 3HP 20HP 400V 3HP 25HP IP20 NEMA1 ...
Page 29: ...3 15 c 200V 25HP 400V 30HP d 200V 30HP 40HP 400V 40HP 75HP ...
Page 51: ...3 37 3 5 Standard Wiring 10V AI1 AI2 AGND E P P ...
Page 72: ...4 6 4 1 4 Example of keypad operation Example 1 Modifying parameters ...
Page 74: ...4 8 4 1 5 Operation control ...
Page 206: ...4 140 Acceleration Deceleration calculation of mode 2 ...
Page 316: ...4 250 6 Timer mode 6 FLASH Timer mode 2 7 Timer mode 7 FLASH Timer mode 3 ...
Page 424: ...REVISIONS Date Manual Number Revision May 2017 4KA72X645T01 First edition ...
Page 425: ......