4-56
direction are set by parameters 06-16 and 06-32.
Auto RUN ( Auto Sequencer) examples are shown in the following pages:-
Example 1.
Single Cycle (06- 00=1,4)
The inverter will run for a single full cycle based on the specified number of sequences, then it will stop. In
this example 4 sequences are set, three in forward direction and one in Reverse.
.Auto Run Mode 06- 00=
【
1
】
(or
【
4
】
),
Frequency 05-01=
【
15
】
Hz, 06- 01=
【
30
】
Hz, 06- 02=
【
50
】
Hz, 06- 03=
【
20
】
Hz
Sequence Run Time 06-16=
【
20
】
s, 06-17=
【
25
】
s, 06-18=
【
30
】
s 06-19=
【
40
】
s,
Direction 06-32=
【
1
】
, 06-33=
【
1
】
, 06-34=
【
1
】
(FWD), 06-35=
【
2
】
(REV),
Unused Sequence Parameters 06-04~ 06-15=
【
0
】
Hz
,
06-20~06-31=
【
0
】
s
,
06-36~06-47=
【
0
】
05-01
06-01
06-02
06-03
06-16
06-17
06-18
06-19
T
Hz
RUN
command
RUN
ON
S1 to S6 auto
run enable
Example 2: Periodic Cycle Run.
Mode: 06- 00=
【
2
】
or
【
5
】
The inverter will repeat the same cycle periodically.
All other Parameters are set same as Example 1. shown above
05-01
06-01
06-02
06-03
05-01
06-01
06-02
06-03
06-16
06-17
06-18
06-19
06-16
06-17
06-18
06-19
T
Hz
RUN
Command
RUN
ON
S1 to S6 auto
Run enable
Example 3. Auto_Run Mode for Single Cycle 06-00=
【
3 or 6
】
Summary of Contents for e510 series
Page 1: ......
Page 8: ...2 1 Chapter 2 Part Number Definition 2 1 Model Part Number...
Page 13: ...3 4 Screw M4 Screw M4...
Page 34: ...3 25 c Three phase 200V 8 10HP 400V 8 15HP E510 Frame 3 E510 Frame 3 NEMA1...
Page 35: ...3 26 d Three phase 200V 15 20HP 400V 20 25HP E510 Frame 4 E510 Frame 4 NEMA1...
Page 43: ...3 34 3 5 2 Single Three phase Model 200V E510 2P5 H E510 201 H E510 202 H E510 203 H...
Page 197: ......