App3-6
Register
No.
Content
abnormity
00
The inverter is normal
20
Over current during decelerating)( OC-D )
01
Inverter over heat)( OH )
21
(OC_S)
02
Over current at stop)( OC )
22
Reserved
03
Under voltage( LV )
23
Under voltage during running( LV-C )
04
Over voltage)( OV )
24
Over voltage at constant speed( OV-C )
05
Reserved
25
Inverter over heat during running( OH-C )
06
External BB( bb )
26
stop at 0 Hz( STP0 )
07
( CTER )
27
Direct start disable)( STP1 )
08
( PDER )
28
Control panel emergency stop( STP2 )
09
(EPR)
29
Keypad operation error)( Err1 )
10
(ATER )
30
Parameter setting error( Err2 )
11
( OL3 )
31
(Err4)
12
Inverter over load( OL2 )
32
Communication failure)
( Err5 )
13
Motor over load(OL1)
33
Communication failure( Err6 )
14
(EFO)
34
( Err7 )
15
External bb E.S )
35
(Err8)
16
( LOC )
36
Reserved
17
Reserved
37
Reserved
18
Over voltage at constant speed
( OC-C )
38
(EPR1)
19
Over current during
accelerating)( OC-A )
39
(EPR2)
2521H
40
Inverter over speed( OVSP )
Sequence input status
0
Terminal S1 1 :“ON” 0:“OFF”
1
Terminal S2 1 :“ON” 0:“OFF”
2
Terminal S3 1 :“ON” 0:“OFF”
3
Terminal S4 1 :“ON” 0:“OFF”
4
Terminal S5 1 :“ON” 0:“OFF”
5
Terminal S6 1 :“ON” 0:“OFF”
Contact output
6
Relay R1
1 :“ON” 0:“OFF”
7
Relay R2
1 :“ON” 0:“OFF”
2522H
9~F
Reserved
Summary of Contents for e510 series
Page 1: ......
Page 8: ...2 1 Chapter 2 Part Number Definition 2 1 Model Part Number...
Page 13: ...3 4 Screw M4 Screw M4...
Page 34: ...3 25 c Three phase 200V 8 10HP 400V 8 15HP E510 Frame 3 E510 Frame 3 NEMA1...
Page 35: ...3 26 d Three phase 200V 15 20HP 400V 20 25HP E510 Frame 4 E510 Frame 4 NEMA1...
Page 43: ...3 34 3 5 2 Single Three phase Model 200V E510 2P5 H E510 201 H E510 202 H E510 203 H...
Page 197: ......