App3-11
4.6 Write in several holding registers [10H]
Specified data are written into the several specified holding registers from the Specified
number,
respectively.
Note: 1. Limit number of read data
,
RTU: 35
,
ASCII:15.
2. Can only Continuous read the address of the same Group.
3. Read data Quantity
≥
1.
(Example)Set SLAVE station No:01, E510 drive as forward run at frequency reference
60.0HZ.
ASCII Mode
Instruction Message Response Message (Normal) Response(Fault)
3AH
STX
3AH
STX
3AH
STX
30H
30H
30H
31H
SLAVE
Address
31H
SLAVE
Address
31H
SLAVE
Address
31H
31H
39H
30H
Function
Code
30H
Function
Code
30H
Function
Code
41H
41H
35H
30H
30H
32H
Error Code
30H
30H
?
31H
Start
Address
31H
Start
Address
?
LRC CHECK
0DH
30H
30H
0AH
END
30H
30H
30H
30H
32H
Quantity
32H
Quantity
30H
?
34H
DATA
Number *
?
LRC CHECK
30H
0DH
30H
0AH
END
30H
31H
First
DATA
31H
37H
37H
30H
Next
DATA
?
?
LRC CHECK
0DH
0AH
END