4-28
00- 07
Main and Alternative Frequency Command Modes
Range
【
0
】
: Main or Alternative Frequency.
【
1
】
: Main Fre Alternative Frequency
¾
When 00 - 07 =
【
0
】
, ,the frequency source is set by the Main frequency parameter 00-05 ( Default)
or by the Alternative frequency parameter 00-06.
Use any of the external terminals S1 to S6 and set the relevant parameter 03-00 to 03-05 =
【
13
】
to
switch from Main to Alternative source..
¾
When 00--07 =
【
1
】
, The frequency command will be the result of setting of main and alternative
frequencies.
00- 08
Communication Frequency Command
Range
【
0.00~650.00
】
Hz
¾
This parameter can be used to set frequency command
¾
This parameter can be used to read the set frequency in communication mode
¾
This parameter is only effective in the communication mode.
00- 09
Frequency Command save on power down (Communication mode)
Range
【
0
】
:
Disable
【
1
】
:
Enable
¾
00-09=
【
0
】
Keypad frequency is saved.
¾
00-09=
【
1
】
Frequency set by communication is saved.
00-10
Initial Frequency Selection
Range
【
0
】
:By Current Freq Command
【
1
】
:By Zero Freq Command
【
2
】
:By 00-11
00-11
Initial Frequency Setpoint
Range
【
0.00~650.00
】
Hz
¾
This parameter is only effective in keypad mode
¾
When
00-10=
【
0
】
,the initial frequency will be current frequency.
¾
When 00-10=
【
1
】
,the initial frequency will be 0.
¾
When 00-10=
【
2
】
,the initial frequency will be as set by parameter 00-11..
00-12
Frequency Upper limit
Range
【
0.01~650.00
】
Hz
00-13
Frequency Lower limit
Range
【
0.00~649.99
】
Hz
¾
When 00-13 and the command frequency are both set to 0.00, if RUN is pressed
”
Stpo” is displayed.
¾
When Frequency command is higher than preset in 00-13 inverter output will ramp up from 0.00 to the
command frequency.
¾
When 00-13> 0, and the frequency command value
≤
00-13, inverter output will ramp up from preset
in lower limit to the command frequency.
Frequency
Upper Limit
Frequency
Lower limit
0
Hz
T
Summary of Contents for e510 series
Page 1: ......
Page 8: ...2 1 Chapter 2 Part Number Definition 2 1 Model Part Number...
Page 13: ...3 4 Screw M4 Screw M4...
Page 34: ...3 25 c Three phase 200V 8 10HP 400V 8 15HP E510 Frame 3 E510 Frame 3 NEMA1...
Page 35: ...3 26 d Three phase 200V 15 20HP 400V 20 25HP E510 Frame 4 E510 Frame 4 NEMA1...
Page 43: ...3 34 3 5 2 Single Three phase Model 200V E510 2P5 H E510 201 H E510 202 H E510 203 H...
Page 197: ......