2. The electronic thermal protection for the AC Drive is as follows:
(1) When the load is within 103% of the AC drive rated current, the operation continues. When the load reaches 150% of rated
current of the AC drive, the operation will continue for 1 minute. (Refer to curve (1) of figure 3)
(2) After the activation of the electronic thermal switch, the AC drive is shut off immediately. (The OL2 light will flash) To resume
the operation, push RESET button or activate an external reset contact wired to Terminal 2.
F_19: Multi-Function Input Terminal 1 = 1~ 5 (1 ~ 6: CPU version v1.9 and above)
F_20: Multi-Function Input Terminal 2 = 1~ 5 (1 ~ 6: CPU version v1.9 and above)
1. F_19 = 1 or F_20 = 1: JOG control (refer to F_09; Jog Frequency Setting):
2. F_19, F_20 = 2 or 6 Multi-speed control (refer to F_08, F_26, F_27; Multi-speeds 1-3 settings):
F_19 = 2 & F_20 = 6:
TM2 SP1 Terminal
TM2 SP1 Terminal
Output Frequency
ON
OFF
F_08
OFF
ON
F_26
ON
ON
F_27
F_19=6 & F_20=2:
TM2 SP1 Terminal
TM2 SP1 Terminal
Output Frequency
ON
OFF
F_26
OFF
ON
F_08
ON
ON
F_27
44
FLUXMASTER 50 INSTRUCTION MANUAL
Summary of Contents for FM50101-X
Page 1: ...www tecowestinghouse com Instruction Manual User Manual...
Page 18: ...External 24V Supply 18 FLUXMASTER 50 INSTRUCTION MANUAL...
Page 33: ...33 FLUXMASTER 50 INSTRUCTION MANUAL 2 6 Mounting Instructions...
Page 53: ...4 Troubleshooting Procedures 53 FLUXMASTER 50 INSTRUCTION MANUAL 4 1 Flow Chart...
Page 54: ...FLUXMASTER 50 INSTRUCTION MANUAL Continued 54...
Page 55: ...FLUXMASTER 50 INSTRUCTION MANUAL Error handling of fault indication of OC OL 55...
Page 56: ...Error handling of fault indication of OV LV 56 FLUXMASTER 50 INSTRUCTION MANUAL...
Page 57: ...57 FLUXMASTER 50 INSTRUCTION MANUAL 1 Motor inoperative...
Page 58: ...FLUXMASTER 50 INSTRUCTION MANUAL 58 2 Motor overheat...
Page 59: ...FLUXMASTER 50 INSTRUCTION MANUAL 3 Unstable motor operation 59...
Page 66: ...Notes 66 FLUXMASTER 50 INSTRUCTION MANUAL...