F_26: SP2 (1 ~ 200Hz) , Multi-speed 2 (Refer to F_19 / F_20)
F_27: SP3 (1 ~ 200Hz) , Multi-speed 3 (Refer to F_19 / F_20)
F_28: Power Up Start = 0 : Power Up start enabled when remote Run command on
= 1 : Power Up start disabled when remote Run command on
(CPU version V2.1 and above)
When F_28 = 1 and control mode is remote control (F_10 = 1), the AC drive can not start if the RUN switch is ON when power is
engaged.The run signal must be toggled off then on to run the AC drive.
F_29: CPU Program Version
F_30: Fault log for last three faults
1. Last three faults: indicate the sequence of the occurrence of faults by the location of decimal point.
x.xx
indicates a
recently occurred fault.
xx.x
indicates the prior fault event.
xxx
. Indicates the earliest fault in the record.
2. After entering the F_30 function, the x.xx trip record will be displayed first. After that, press
▲
button and you can read activity
in a chronological order.
xx.x
➔
xxx
.
➔
x.xx
➔
xxx,
consecutively.
3. After entering F_30 function, if the RESET button is pressed, the trip record will be cleared. (Indication display
-.--, --.-,
and
---.
results)
4. When the content of trip indicates O.CC, it will indicate the latest trip code is OC-C and so on.
48
FLUXMASTER 50 INSTRUCTION MANUAL
Summary of Contents for FM50101-X
Page 1: ...www tecowestinghouse com Instruction Manual User Manual...
Page 18: ...External 24V Supply 18 FLUXMASTER 50 INSTRUCTION MANUAL...
Page 33: ...33 FLUXMASTER 50 INSTRUCTION MANUAL 2 6 Mounting Instructions...
Page 53: ...4 Troubleshooting Procedures 53 FLUXMASTER 50 INSTRUCTION MANUAL 4 1 Flow Chart...
Page 54: ...FLUXMASTER 50 INSTRUCTION MANUAL Continued 54...
Page 55: ...FLUXMASTER 50 INSTRUCTION MANUAL Error handling of fault indication of OC OL 55...
Page 56: ...Error handling of fault indication of OV LV 56 FLUXMASTER 50 INSTRUCTION MANUAL...
Page 57: ...57 FLUXMASTER 50 INSTRUCTION MANUAL 1 Motor inoperative...
Page 58: ...FLUXMASTER 50 INSTRUCTION MANUAL 58 2 Motor overheat...
Page 59: ...FLUXMASTER 50 INSTRUCTION MANUAL 3 Unstable motor operation 59...
Page 66: ...Notes 66 FLUXMASTER 50 INSTRUCTION MANUAL...