36
Address
Parameter
Name & Function
Default Unit
Setting
Range RS232 RS485
Output time setting for Mechanical Brake Signal
Cn003
Brake Signal Timing Sequence
:
Implementation a pin for dynamic brake signal(BI) as a output
signal before to perform this function. Refer to sequence
diagram above.
Note: Signal logic level status: 1 = ON. 0 = OFF.
Refer to section5-6-1 for setting contact the high & Low logic
levels.
0
msec
-2000
│
2000
511H 0003H
Motor rotate direction.(Inspect from the load side)
CCW
CW
When Torque or Speed Command value is Positive, the
setting of Motor retation direction are:
Explanation
Setting
Torque Control
Speed Control
0
Counter ClockWise(CCW)
Counter
ClockWise (CCW)
1
ClockWise (CW)
Counter
ClockWise (CCW)
2
Counter
ClockWise (CCW)
ClockWise(CW)
Cn004
3
ClockWise (CW)
ClockWise (CW)
0
X
0
│
3
512H 0004H