37
Address
Parameter
Name & Function
Default Unit
Setting
Range RS232 RS485
Encoder pulse output scale.
★
Cn005
For default set to the rated encoder number of pulses per
revolution, such as 2500ppr.
Encoder ppr can be scaled by setting a ppr in the range of 1 to
the rated ppr of the encoder for scaling purpose.
PPR = Pulse per revolution.
Ex:encorder rated precision is 2000 ppr, If you setting
Cn005 =1000, the output is 1000ppr.
Encoder
pulse per
rotation
pulse
1
│
Encoder
pulse per
rotation
513H 0005H
Cn006
Reserve
─
─
─
─
─
Speed reached preset.
Cn007
Speed preset level for ClockWise or Counter ClockWise
rotation.
When the speed is greater then preset level in Cn007 the Speed
reached output signal INS will be activated..
Rated
rpm × 1/3
rpm
0
│
4500
515H 0007H
Brake Mode
Selectable Brake modes for Servo off, EMC and CCW/CW drive
inhibit.
Setting
Explanation
Dynamic brakes
Mechanical brakes
0
No
No
Cn008
1
No
Yes
0
X
0
│
3
516H 0008H