41
Address
Parameter
Name & Function
Default Unit
Setting
Range RS232 RS485
Cn027 Reserve
─
─
─
─
Cn028 Reserve
─
─
─
─
Reset parameters.
Setting
Explanation
0
Disabled
★
Cn029
1
Reset all Parameters to default ( Factory setting)
0
X
0
│
1
5FDH 001DH
Servo motor model code
★
Cn030
Servo model code can be display and checked with parameter
dn-08, refer 3-2-2 dn-08 table for more information.
Attention
:
Before operate your servo motor., check this parameter
setting is compatible for servo drive and motor. If there has any
incompatible problem contact supplier for more information.
Default
X
X
50BH 001EH
Cooling fan running modes
(Available for JSDEP-50 & JSDEP-75)
Setting
Explanation
0
Auto-run by internal temperature sensor.
1
Run when Servo ON
2
Always Running.
Cn031
3
Disabled.
0
X
0
│
3
Low Voltage Protection(AL-01) auto-reset selection
This parameter(AL-01) could be set the method of Low Voltage
Protection.
Setting
Explanation
0
As servo on, it shows AL-01 low voltage alarm
immediately when it detect low voltage, and after
eliminating the situation, to reset it, servo off is a must.
Cn031.1
1
It shows BB(baseblock) immediately when it detect low
voltage, and after eliminating the situation, drive would be
auto-reset and displayed Run.
0
X
0
│
1
50EH 001FH
Speed feed back smoothing filter
Cn032 Restrain sharp vibration noise by the setting and this filter also
delay the time of servo response.
500
Hz
1
│
2500
546H 0020H
Speed Feed-forward smoothing filter
Cn033
Smooth the speed feed-forward command.
500
Hz
1
│
1000
51EH 0021H
Torque command smoothing filter
Cn034 Restrain sharp vibration noise by the setting and this filter delay
the time of servo response.
500
Hz
0
│
5000
C17H 0022H